ConfiGuraTion anD funCTion of The moDules
English
Object
class
Instance
Attri-
butes
Ac-
cess
Length
byte
Area
Default Short Description
Error Action
9
1 to 16
5
Get/
Set
2
0x0000
to
0xFFFF
0x0000 Action after failure or
offline
0: Error Value
1: Hold last state
Error Value
9
1 to 16
6
Get/
Set
2
0x0000
to
0xFFFF
0x0000 Action after failure or
offline
config�uration of the Process data
Either a static input or a static output assembly are available for the transfer of process data over an I/O con-
nection. Selected attributes are joined into one object in these assemblies, in order to be able to be jointly
transferred as process data over an I/O connection.
The process data can be accessed either cyclically using the connections variants “polled I/O”, “bitstrobbed
I/O” or “change of state” (if the entry values change) or acyclically using explicit messages.
The acyclic access paths are: class 4 instance 1 attribute (input)
class 4 instance 2 attribute (output)
per module (main connector pro module (hub, inside module, RIO module 8645):
2 data bytes for inputs (sensors or initiators)
2 data bytes for outputs (actuators or valves)
per RIO-Module 8640:
4 data bytes for inputs (sensors or initiators)
3 data bytes for outputs (actuators or valves)