Rainbow Electronics MG260 User Manual
Page 88
![background image](/manuals/281850/88/background.png)
FLYFOT-MG260-MODULE
Page: 88 / 246
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.
RD : Reject Duplicates, b2=1 to instruct the SC to reject an SMS-SUBMIT
for an SM still held in the SC which has the same
same
MTI : Message Type Indicator
b1=0 & b0=0 -> SMS-DELIVER (in the direction SC to MS)
b1=0 & b0=1 -> SMS-SUBMIT (in the direction MS to SC)
In text mode
(24 hours). This means that one byte can describe different values :
VP value
Validity period value
0 to 143
(VP + 1) x 5 minutes (up to 12 hours)
144 to 167
12 hours + ( (VP -143) x 30 minutes )
168 to 196
(VP - 166) x 1 day
197 to 255
(VP-192) x 1 week
interworking with a certain type of telematic device. For example, 0x22 is for
group 3 telefax, 0x24 is for voice telephone, 0x25 is for ERMES (European
Radio Messaging System).
text is not supported. Only GSM default alphabet, 8 bit data and UCS2
alphabet are supported.
9.19 Select TE character set +CSCS
Description
This command informs the ME which character set is used by the TE. The ME can convert each character
of entered or displayed strings. This is used to send, read or write short messages. See also +WPCS for the
phonebooks character sets.
Syntax
Command syntax : AT+CSCS=
Command
Possible responses
AT+CSCS=“GSM”
Note : GSM default alphabet
OK
Note : Command valid
AT+CSCS=?
Note : Get possible values
+CSCS: (“GSM”,”UCS2”,”HEX”)
OK