Rainbow Electronics MG260 User Manual
Page 203
FLYFOT-MG260-MODULE
Page: 203 / 246
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.
Forward Activated indicator for Line 1.
Note :Call Forward is active for Line 1.
AT+CPHS=2,6,22
+WCPI: 22,0
Note :Get the current status for Line 2
OK
Mailbox number.
Note :Mailbox number for Line2 is not
available.
AT+CPHS=2,6,17
+CME ERROR: 3
Wrong data field
AT+CPHS=2,6,22
+CME ERROR: 3
Note :Get the current status for Line 2
Note :CPHS Feature is not allowed
Mailbox number.
AT+CPHS=0,6
OK
Note :Deactivation of CPHS Info
Note :No effect.
feature.
Defined values
: value indicating the field of CPHS information (see appendix 19.14)
If
1 : data field is unset
When all CPHS information are requested, the status correspond to a bit field
(see appendix 19.14)
Note : The field CSP service ( = 1) is used to set or not the CSP feature at the initialisation.
18.32 FLYFOT customer service profile: +WCSP
Description
This indication indicates if a service is accessible to the customer. This is the response to the
AT+CPHS 2,7,
Syntax
Command : AT+CPHS=2,7,
Response syntax: +WCSP:
Command
Possible responses
AT+WCSP=?
ERROR
AT+WCSP? ERROR
AT+CPHS=2,7
+CME ERROR: 3
Note
:Syntax
error
AT+CPHS=2,7,9
+WCSP: 9,1
Note :Get the current status for
OK