Rainbow Electronics MG260 User Manual
Page 163
FLYFOT-MG260-MODULE
Page: 163 / 246
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.
entered
1) OK
2) If sending successfully
SEND SUCCESS
3) If error is occurred
SEND FAIL
AT+ CIPSEND =<
data length >
Response
This command is used to send
fixed length of data. in this way
termination symbol is not used any more.
1) OK
2) If sending successfully
SEND SUCCESS
3) If error is occurred
SEND FAIL
Parameter
< data length > the length of data that would be sent
Reference
Note : length less than 1024
17.3 AT+CIPCLOSE
AT+CIPCLOSE Close connection
Action command
AT+
CIPCLOSE
Response
This command is used to close TCP or UDP connection. After this
command, data can not be sent or received any more. However,
the PDP context is still active when connecting GPRS network
and CSD is still connected when connecting GSM network.
Parameter
none
Reference
Note
17.4 AT+CIPSHUT
AT+CIPSHUT Detach from GPRS network
Action command
AT+
CIPSHUT
Response
This command is used to shut down connection After this command
executed, it will generally get a different IP address when starting up a