Command
Possible responses
AT+CRC=0
Note : Extended reports disabled
OK
Note : Command valid
AT+CRC=1
Note : Extended reports enabled
OK
Note : Command valid
AT+CRC?
+CRC: 1
OK
AT+CRC=?
+CRC: (0,1)
OK
Defined values:
0: disable extended reports
1: enable extended reports
16.5 DTE-DCE local rate reporting +ILRR
Description :
This parameter controls whether the extended-format “+ILRR:
the DCE to the DTE or not. The
DTE-DCE speed rate.
If enabled, the intermediate result code is transmitted in an incoming or outgoing data call, after any data
compression report, and before any final result code (CONNECT).
Syntax :
Command syntax : AT+ILRR =
Command
Possible responses
AT+ILRR=0
Note : Local port rate report disabled
OK
Note : Command valid
AT+ILRR=1
Note : Local port rate report enabled
OK
Note : Command valid
AT+ILRR?
+ILRR: 1
OK
AT+ILRR=?
+ILRR: (0,1)
OK
Defined values:
0: disable local port rate report
1: enable local port rate report