Rainbow Electronics MG260 User Manual
Page 50

FLYFOT-MG260-MODULE
Page: 50 / 246
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.
AT+THOC?
Note: Get the handover counter.
+THOC: 0
OK
AT+THOC=?
OK
Note: succeed
AT+THOC
AT+THOC=1
+CME ERROR: 3
Note: not support
6.7
Cell environment description +CCED
Description :
This command can be used by the application to retrieve the parameters of the main cell and of up to six
neighbouring cells.
There are two possible methods for the external application to ascertain these cell parameters: on request by the
application or automatically by the product every 5 seconds.
Automatic mode is not supported during communication or registration.
Syntax :
Command syntax: AT+CCED=
Command
Possible responses
AT+CCED=0
Note: One shot
requested
+CCED:
460,00,109f,4ee1,31,25,48,0,0,0,0,0,0,460,00,1081,232b,28,21,21,460,00,10
c6,cdc6,35,36,18,460,00,109f,cd2a,7,34,17,460,00,109f,cd2b,14,44,15,460,00,10c6,
cdc7,34,32,14,0
OK
AT+THOC=?
AT+CCED?
+CME ERROR: 3
Note: not support
Defined values :
1: Automatic shots requested
2: Stop automatic shots
RxLev Full, RxLev Sub, RxQual, RxQual Full, RxQual,Sub, Idle TS. if the Cell Identity is not available MCC,
MNC, LAC, BSIC, BCCH, Freq (absolute), RxLev, RxLev Full, RxLev Sub, RxQual, RxQual Full, RxQual
Sub,Idle TS
2: Neighbour1 to Neighbour6 : if the Cell Identity is available MCC, MNC, LAC,CI, BSIC, BCCH
Freq(absolute), RxLev if the Cell Identity is not available MCC,MNC, LAC,, BSIC, BCCH Freq (absolute),