beautypg.com

11 formulation (cont.) procedure (cont.) – Ohaus Voyager Balances User Manual

Page 28

background image

22

3.11 Formulation (Cont.)

Procedure (Cont.)

FORMULATIONS BY WEIGHT (cont.)

• Press Enter button, a NAME menu appears with the

value shaded.

• Press Enter button, ENTER COMPONENT WEIGHT

menu is displayed.

• Using the arrow buttons, enter the component weight

for item 1 in the formula.

• Press Enter button when desired weight is entered.

The NAME menu appears again. Repeat steps

(identified with arrow R on previous page) and enter

the component names and weight values for the first

formula. Samples shown at left.

Go Back

Help

Print

Enter

FORMULATION -- FORMULA1

0%

89%

GRAMS

STABLE

PREVIOUS

MAIN

CONTRAST

NEXT

20.00

90% 110%

A1 = 20.00 DIFF WT = 0.00

FORMULATION -- FORMULA1

0%

89%

GRAMS

STABLE

PREVIOUS

MAIN

CONTRAST

NEXT

30.00

90% 110%

A2 = 30.00 DIFF WT = 0.00

FORMULATION -- FORMULA1

0%

89%

GRAMS

STABLE

PREVIOUS

MAIN

CONTRAST

NEXT

50.00

90% 110%

A3 = 50.00 DIFF WT = 0.00

• When all of the entries have been made, select SAVE

TO LIBRARY in the FORMULATION SETUP menu,

and then select RUN, press Enter button. The

balance displays the first component of the formula

and the required weight.

• Place a container on the pan and tare by pressing

>O/T< button.

• Add the required amount to the container until thebal-

ance indicates 100% on the bar graph and the proper

weight.

• Using the arrow buttons, select NEXT shown at the

bottom of the screen and press Enter button. The

second component of the formula is displayed. Add

the required weight. Select NEXT and repeat the

procedure for all items in the formula.

• When you have completed weighing all items in the

formula, select NEXT again and a display appears

which indicates the Target Weight, Result and Differ-

ence Weight for the formula. See display below.

• To select previously stored formulations, select

FORMULATION menu and select RECALL. This will

bring up the library of formulations.

Example using a total of 100 grams in the formulation.

FORMULA1 TARGET RESULT DIFF WT
A1 20.00 20.05 0.05
A2 30.00 30.07 0.07
A3 50.00 50.00 0.15
TOTAL 100.00 100.27 0.27

MAIN MENU

CHANGE UNITS

SET BALANCE

RETURN TO

WEIGH

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING
DIFFERENTIAL WEIGHING

FORMULATE

QUICK CHECK
STATISTIC
DENSITY

FORMULATION

SETUP

R
RECALL
EXIT TO WEIGH

FORMULA SETUP

LIBRARY NAME
WEIGH TYPE

WEIGHT

SET REFERENCE

NUMBER OF ITEMS 0

SETUP
SAVE TO LIBRARY
RUN
EXIT TO WEIGH

MAIN MENU

CHANGE UNITS

SET BALANCE

RETURN TO

WEIGH

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING
DIFFRENTIAL WEIGHING

FORMULATE

QUICK CHECK
STATISTIC
DENSITY

FORMULATION

SETUP

R
RECALL
EXIT TO WEIGH

FORMULA SETUP

LIBRARYNAME

WEIGH TYPE

SET REFERENCE
NUMBER NUMBER
SETUP
SAVE TO LIBRARY
RUN
EXIT TO WEIGH

SET ITEM NUMBER

/ TO SCROLL CHARACTERS
/ TO MOVE CURSOR
TO ACCEPT
TO ABORT

3

MAIN MENU

CHANGE UNITS

SET BALANCE

RETURN TO

WEIGH

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING
DIFFERENTIAL WEIGHING

FORMULATE

QUICK CHECK
STATISTIC
DENSITY

FORMULATION

SETUP

R
RECALL
EXIT TO WEIGH

FORMULA SETUP

LIBRARY NAME FORMULA1
WEIGH TYPE WEIGHT
SET REFERENCE
NUMBER OF ITEMS 3

SETUP

SAVE TO LIBRARY
RUN
EXIT TO WEIGH

MAIN MENU

CHANGE UNITS

SET BALANCE

RETURN TO

WEIGH

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING
DIFFERENTIAL WEIGHING

FORMULATE

QUICK CHECK
STATISTIC
DENSITY

FORMULATION

SETUP

R
RECALL
EXIT TO WEIGH

FORMULATION SETUP

LIBRARYNAME
WEIGHT TYPE
SET REFERENCE
NUMBEM NUMBER 0

SETUP

SAVE TO LIBRARY
RUN
EXIT TO WEIGH

# NAME VALUE

1 A1

0.00

2
3

COMPONENT NAME

UP/DOWN TO SCROLL CHARACTERS
LEFT/RIGHT TO MOVE CURSOR
ENTER TO ACCEPT
BACK TO QUIT

A1

MAIN MENU

CHANGE UNITS

SET BALANCE

RETURN TO

WEIGH

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING
DIFFERENTIAL WEIGHING

FORMULATE

QUICK CHECK
STATISTIC
DENSITY

FORMULATION

SETUP

R
RECALL
EXIT TO WEIGH

FORMULATION SETUP

LIBRARYNAME
WEIGHT TYPE
SET REFERENCE
NUMBEM NUMBER 0

SETUP

SAVE TO LIBRARY
RUN
EXIT TO WEIGH

# NAME VALUE

1 A1 20.00
2 A2 30.00
3 A3

50.00

MAIN MENU

CHANGE UNITS

SET BALANCE

RETURN TO

WEIGH

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING
DIFFERENTIAL WEIGHING

FORMULATE

QUICK CHECK
STATISTIC
DENSITY

FORMULATION

SETUP

R
RECALL
EXIT TO WEIGH

FORMULA SETUP

LIBRARY NAME FORMULA1
WEIGH TYPE WEIGHT
SET REFERENCE
NUMBER OF ITEMS 3
SETUP

SAVE TO LIBRARY

RUN
EXIT TO WEIGH

MAIN MENU

CHANGE UNITS

SET BALANCE

RETURN TO

WEIGH

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING
DIFFERENTIAL WEIGHING

FORMULATE

QUICK CHECK
STATISTIC
DENSITY

FORMULATION

SETUP

R
RECALL
EXIT TO WEIGH

FORMULA SETUP

LIBRARY NAME FORMULA1
WEIGH TYPE WEIGHT
SET REFERENCE
NUMBER OF ITEMS 3
SETUP
SAVE TO LIBRARY

RUN

EXIT TO WEIGH