Differential weighing stores tare and weight values so a sample can be dried and the difference calculated at a later
time. Up to 100 samples can be stored. samples can be added to the applications library. Batch and individual
samples can be accommodated.The features in the Voyager balance for differential weighing include:

RECALL - When selected, brings up previously stored library names associated with each sample.
LIBRARY NAME - A name up to 10 characters can be entered and stored to identify the sample item.
TARE WEIGHT - This is the tare weight of the container holding the samples, can be set to NO or YES.
AUTO TARE - Used when it is desired to automatically tare the storing container's weight, can be set to NO or YES.
AUTO SAMPLE DETECT - This feature is used for repetitive sample weighing, can be set NO or YES.
MODE - Can be set to INDIVIDUAL or BATCH.
FINAL RESULT - Can be set to show results in PERCENTAGE or WEIGHT.
SAMPLE NUMBERS - Desired number of samples can be entered.
SAVE TO LIBRARY - Permits all entries to be saved to the Library.
EXIT TO WEIGH - When selected, will exit to standard weighing mode.

3.10

Differential Weighing

Go Back

Help

Print

Enter

or

Go Back

Help

Print

Enter

DIFF WEIGHING -- NAME-- SAMPLE 1

0%

100%

GRAMS

STABLE

EDIT

MAIN

CONTRAST

ENTER

0.00

INIT WT=

0.00

TARE WT=

0.00

WEIGHT

0%

100%

GRAMS

STABLE

MOVE HIGHLIGHT

MAIN MENU

CONTRAST

Procedure

• Press

arrow button to select MAIN MENU.

• Press Enter button.
• Using the arrow buttons, select CHANGE MODE.
• Press Enter button.

• Press

or

arrow button and select DIFF-

WEIGHING.

• Press Enter button.

• Press

or

arrow button and select RECALL,

SETUP or EXIT TO WEIGH.

• Press Enter button. If RECALL was selected, you

can scan the library and select the desired item.

• If SETUP is selected, continue by pressing Enter

button.

• On the SETUP MENU, using the arrow buttons and

Enter button, select YES or NO for each of the
following items on the menu: TARE WEIGHT, AUTO
TARE, AUTO SAMPLE DETECT; for MODE, select
either INDIVIDUAL or BATCH; for FINAL RESULT,
select either WEIGHT or PERCENT; for SAMPLE
NUMBERS, enter the desired number of samples to
be weighed; enter a name for LIBRARY NAME; scroll
down using the arrow button and select SAVE TO
LIBRARY by pressing Enter button.

• Scroll to RUN, press Enter button. DIFF WEIGHING-

SAMPLE 1 is displayed as shown below.

MAIN MENU

CHANGE UNITSPART

S

ET BALANCE

RETURN TO

WEIGH

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILLING
ANIMAL WEIGHING
CHECK WEIGHING

DIFF WEIGHING

FORMULATION
QUICK CHECK
STATISTICS
DENSITY

MAIN MENU

CHANGE UNITSPART

S

ET BALANCE

LIBRARY

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING

DIFF WEIGHING

FORMULATION
QUICK CHECK
STATISTICS
DENSITY

DIFF WEIGHING

SETUP

RECALL

RESUME
EXIT TO WEIGH

MAIN MENU

CHANGE UNITSPART

S

ET BALANCE

RETURN TO

WEIGH

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING

DIFF WEIGHING

FORMULATION
QUICK CHECK
STATISTICS
DENSITY

DIFF WEIGHING

SETUP

RECALL
RESUME
EXIT TO WEIGH

MAIN MENU

CHANGE UNITSPART

S

ET BALANCE

RETURN TO

WEIGH

CALIBRATION

CUSTOM MENU

CHANGE MODE

CHANGE MODE

BASIC WEIGHING
PARTS COUNTING
FILL
ANIMAL WEIGHING
CHECK WEIGHING

DIFFERENTIAL WEIGHING

FORMULATE
QUICK CHECK
STATISTIC
DENSITY

DIFF WEIGHING

S

RECALL
RS

ETUP

EXIT TO WEIGH

SETUP

TARE WEIGHT NO
AUTO TARE NO
AUTO SAMPLE DETECT NO
MODE INDIVIDUAL
FINAL RESULT WEIGHT
SAMPLE NUMBERS 3
LIBRARY NAME NAME

SAVE TO LIBRARY