beautypg.com

Electrical environmental data, Electrical, Environmental data – Xerox MAX 200 User Manual

Page 282

background image

280

Technical data

Electrical

Electrical specifications

210 to 246 VAC

Voltage

Scanner

120 VAC

Printer

Single phase 214 to 250 VAC

Three phase 185 to 215 VAC

Current (Amps)

Scanner

20 A

Printer

30 A

Power consumption (Watts)

Scanner

Printer

Running

1100

5800

Standby

1000

5100

Environmental data

Operating range

Relative humidity

15% to 85%

Temperature

50

0

F to 90

0

F

Heat output

Running

11,068 BTU/hr.

Standby

2700 BTU/hr.

Audible noise (scanner and printer)

Running

49.5 db (A) or less

Standby

64 db (A) continuous

72 db (A) maximum

Ozone

Concentration based on simulation model:
Daily copy volume: 8250 copies/8 hours
Room size: 17 m

3

0 Air changes per hour
77.6 ug/min
0.009 ppm (time weighted average)
0.016 ppm (peak) threshold limit value (0.10
ppm)

Total dust

0.04 mg/m

3

threshold limit value (10

mg/m

3

)

Organics

<10ppb