Serial i/o setup] area, Port select] area, To pc button – Panasonic WR-DA7 User Manual
Page 156: Rs button, Baud rate] area
![background image](/manuals/172776/156/background.png)
Receive Indicator
The window has receive indicators in the
[taskbar]. A
indicator blinks
when data is received at the
MIDI IN connection, an
indicator blinks
when data is received at the RS 422/485 terminal, and a
indicator
blinks when data is received at the
TO PC terminal.
[SERIAL I/O SETUP] Area
[PORT SELECT] Area
The DA7 has a
TO PC connector port and an RS422/485 serial port on the
Rear Panel. These ports are used for attaching a Mac O/S or Windows O/S
computer platform to the DA7. Only one port can be used at a time. You
must select either
or
in the
[PORT SELECT] area of the
window. The default setting is
. The
[MIDI SETUP] area reflects back
to this selection(See
[MIDI SETUP] on page 11-3). When using one of the
serial ports you need to assign the
to at least one column of the port
settings in the
[MIDI SETUP] area.
Button
This button selects
TO PC on the Rear Panel for the serial I/O port.
Cursor to the button, and press the
ENTER button. The Mac HSKO 1Mhz
clock is active for this selection.
Button
This button selects RS485 for the serial I/O port. Cursor to the button,
and press
ENTER.
[BAUD RATE] Area
This area offers baud rates for the serial
I/O port. To set a baud rate, cursor to
the
[BAUD RATE] area, select either
,
[9.6k], [19.2k], [38.4k],
[62.5k] or [125k] using the JogDial, and press the ENTER button. The
initial setting is
[31.25k]. When [31.25k], [62.5k] or [125k] is selected, a
clock is transmitted. Transmission of the 2Mhz clock turns the serial port off
or on. For RS485,
[31.25k] cannot be set; the initial setting for RS485 is
[38.4k].
C h a p t e r 1 1
D A 7 U s e r s ’ G u i d e
11
-
2
11
MIDI
SERIAL I/O SETUP Area