NewTek TriCaster TC1 (2 RU) User Manual
Page 105
P a g e | 89
Together, the
Vert Position
,
Horiz Position
and
Phase
settings let you tweak synchronization to arrive at an
optimum match between devices. Typically, these settings are fine-tuned with the aid of a downstream
vectorscope and waveform monitor. (A discussion of these adjustments goes beyond the scope of this
manual, but a quick online search for the keywords “genlock” and “adjust” turns up a number of excellent
references).
R
EFERENCE
T
YPE
The ‘bi
-
level’ ref
erence signal long used for standard definition television is often used for genlocking both
SD and HD installations. However, the
HD (Tri-level)
reference sources are also supported by the
Reference
Type
settings option.
Notes: Reference Type options do not appear for SD sessions. Also note that 1080/59.94p Tri-level genlock
signals are not supported.
C
ENTER
F
REQUENCY
This setting is applied when a genlock reference signal is
not
in use. To adjust the setting, supply color bars
to an input and pass video output to a downstream vectorscope. The vectorscope display is completely
stable when
Center Frequency
is properly adjusted.
Note: See also Section 8.1.1, Frame Sync .