Together, the

Vert Position

,

Horiz Position

and

Phase

settings let you tweak synchronization to arrive at an

optimum match between devices. Typically, these settings are fine-tuned with the aid of a downstream
vectorscope and waveform monitor. (A discussion of these adjustments goes beyond the scope of this

manual, but a quick online search for the keywords “genlock” and “adjust” turns up a number of excellent

references).

R

EFERENCE

T

YPE

The ‘bi

-

level’ ref

erence signal long used for standard definition television is often used for genlocking both

SD and HD installations. However, the

HD (Tri-level)

reference sources are also supported by the

Reference

Type

settings option.

Notes: Reference Type options do not appear for SD sessions. Also note that 1080/59.94p Tri-level genlock
signals are not supported.

C

ENTER

F

REQUENCY

This setting is applied when a genlock reference signal is

not

in use. To adjust the setting, supply color bars

to an input and pass video output to a downstream vectorscope. The vectorscope display is completely
stable when

Center Frequency

is properly adjusted.

Note: See also Section 8.1.1, Frame Sync .