When the message prompts replacing consumables/maintenance parts or cleaning, the
corresponding counter that requires consumable replacement/maintenance part replacement/
cleaning is highlighted.
Counters will appear highlighted when:

The page count after replacing the consumable reaches 95% of the value configured in

Specifying the Cycle to Replace Consumables [Life Counter Alarm Setting] (page 232)

in the

Software Operation Panel. (For brake roller/pick roller/separator roller counters)

The scanner determines that the condition of the roller has exceeded the threshold that can be
corrected, by monitoring the wear on the roller. (For assist roller counter)

The page count after cleaning reaches 100% of the value configured in

Scanner Cleaning Cycle

[Cleaning Cycle] (page 231)

in the Software Operation Panel. (Cleaning counter)

The amount of remaining ink reaches below 33%. This is only displayed when the imprinter is
installed. (For [Ink Level:Front] / [Ink Level:Back])

5

Take measures according to the contents of [Information].
Follow the instructions in the message if it prompts consumable replacement/cleaning/
maintenance part replacement.
For information on how to replace consumables, refer to the following:

Replacing the Pick Roller (page 145)

Replacing the Separator Roller (page 148)

Replacing the Brake Roller (page 153)

Replacing the Print Cartridge (page 158)

For details about cleaning, refer to

Daily Care (page 121)

.

Maintenance parts (assist roller) require a service engineer to perform replacement.
For details, contact a service engineer. Refer to the contact information in the Contact List or the
Contact for Inquiries section in Safety Precautions bundled with this product and make an
inquiry.
If the message prompts regular maintenance, please have the scanner checked by a service
engineer for regular maintenance/inspection.
For details, contact a service engineer. Refer to the contact information in the Contact List or the
Contact for Inquiries section in Safety Precautions bundled with this product and make an
inquiry.

How to Use the Operator Panel