The browser ingredient setup is complete, Instrument setup from the browser, 8 target weight tolerance pull down menu – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 66: Speed selection

HI-3010 Filler/Dispenser/IBC
50
Service Manual
FIG. 4-108 TARGET WEIGHT TOLERANCE PULL
DOWN MENU
Step 30. If you choose weight:
•
Double click in the Min. Weight field and
enter the new Minimum target weight tol-
erance.
•
Double click in the Max. Weight field and
enter the new Maximum target weight tol-
erance.
Step 31. If you choose percentage:
•
Double click in the Min. percent (%) field
and enter the new Minimum target weight
tolerance.
•
Double click in the Max. percent (%) field
and enter the new Maximum target weight
tolerance.
Step 32. Click on the Speed pull down menu to select Single
or Dual Speed. (See Fig. 4-109)
FIG. 4-109 SPEED SELECTION
Step 33. Click on the Enter Parameters button to set the
entries.
Step 34. If you have more than one ingredient you want to
configure, go back to the previous page and select a
new ingredient and repeat the Ingredient Adjust-
ment procedures. Continue this process until all the
ingredients you want to use in this fill have been
configured.
The Browser Ingredient Setup is Complete
Instrument Setup from the Browser
Step 1. From the Configuration page click on Instrument
Setup. (See Fig. 4-110) The Instrument Setup page
appears. (See Fig. 4-111)
FIG. 4-110 CONFIGURATION PAGE/SELECT
INSTRUMENT SETUP