Mechanical Installation
Installing the HI 3010 in a Panel
Panel Cutout Specifications
Enclosure Size Requirements:
•
Overall depth of the enclosure must be a
minimum of 8.5" to allow for the 2" clear-
ance between the rear panel of the HI 3010
Filler/Dispenser and the inside surface of the
rear panel of the enclosure. (See Fig. 3-1)
•
There must be a 1" clearance completely
around the bezel and other installed units.
FIG. 3-1 REAR PANEL CLEARANCE REQUIRE-
MENT
Dimensions of the panel cutout. (See Fig. 3-2)
•
8.94” ±.06 (227.076mm ± 1.52mm) Wide
•
6.625” ±.06 (168.26mm ± 1.52mm) High
FIG. 3-2 PANEL CUTOUT DIMENSIONS
Installing the HI 3010 Filler/Dispenser
Step 1. Make sure that all Electrostatic Discharge (ESD)
precautions are taken before and during installation.
Step 2. The Filler/Dispenser comes with a NEMA 4 & 4X
rated compression gasket. Slide the gasket over the
rear of the instrument until the gasket is flush with
the back side of the front panel. (See Fig. 3-3)
FIG. 3-3 PANEL MOUNT INSTALLATION
Step 3. Gently slide the Filler/Dispenser with the gasket
into the cutout in the enclosure front panel or door
until the gasket is flush with the enclosure front
panel. (See Fig. 3-4) Be sure to secure the instru-
ment with both hands when installing.
Step 4. Line up the instrument’s tapped holes with the
through holes in the enclosure front panel.
8.94" (227.076)