Devicenet parameters, About the devicenet parameters, Setup menu/devicenet – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 60: Devicenet menu/baud rate, Setup menu set cl ock - > devicenet - > et her net

HI-3010 Filler/Dispenser/IBC
44
Service Manual
Step 18. Check Table 4-2 for the time zone you are in.
Step 19. Press the right or left arrow until the correct time
zone appears. For example Pacific Standard Time is
-8.
Step 20. Press the Enter button to set the entry.
Step 21. Press the Exit button to return to the SETUP
MENU.
DeviceNet Parameters
About the DeviceNet Parameters
DeviceNet is a low-level network designed to connect the
Filler/Dispenser to higher-level controllers such as PCs,
PLCs or embedded controllers.The DeviceNet Network is an
open, global industry-standard communication network
designed to provide an interface through a single cable from
a programmable controller or PC directly to all HI 3000
Series products as well as smart devices such as sensors,
push buttons, motor starters, simple operator interfaces,
drives and other weight modules. With DeviceNet the user
can monitor or control multiple applications from one dis-
play and allows 3rd party I/O to be easily added to any sys-
tem. You no longer have to hard-wire each device to an I/O
module or I/O block. The network also provides access to
the intelligence present in the instruments for superior diag-
nostics and troubleshooting to help increase system up time.
The DeviceNet network lets you monitor your plant-floor
devices from a central location and reconfigure them as your
needs change or service them as required. You can, for
example, configure the Filler/Dispenser modules for differ-
ent applications.
PARAMETER:DEVICENET BAUD RATE
RANGE: 125K, 250K, 500K
DEFAULT: 125K
PARAMETER:DEVICENET NODE ADDRESS
RANGE: 0-64
DEFAULT: 0
Step 1. Press the Down arrow until the cursor is in front of
DeviceNet. (See Fig. 4-91)
FIG. 4-91 SETUP MENU/DEVICENET
Step 2. Press the Enter button. The DeviceNet Menu
appears with cursor in front of Baud Rate. (See Fig.
4-92)
FIG. 4-92 DEVICENET MENU/BAUD RATE
Step 3. Press the right or left arrow buttons to select the
Baud Rate you want.
+12
IDLE: International Date Line
East
NZST: New Zealand Standard
Wellington, NZ
Fiji
Marshall Islands
+13
Rawaki Island
+14
Line Islands
WEST OF GREENWICH
-1
WAT: West Africa
Azores
Cape Verde Islands
-2
AT: Azores
-3
Brasilia, Brazil
Buenos Aires, Argentina
Georgetown, Guyana
-3:30
Newfoundland
-4
AST: Atlantic Standard
Caracas, Venezuela
La Paz
-5
EST: Eastern Standard
Bogota, Colombia
Lima, Peru
New York, NY, USA
-6
CST: Central Standard
Chicago, Illinois, USA
Mexico City, Mexico
Saskatchewan, Canada
-7
MST: Mountain Standard
Phoenix, Arizona
Denver, Colorado
-8
Pacific Standard
Seattle, Washington
Portland, Oregon
San Francisco, CA
-9
YST: Yukon Standard
-10
AHST: Alaska-Hawaii Standard
CAT: Central Alaska
HST: Hawaii Standard
Anchorage, Alaska
Honolulu, Hawaii
-11
NT: Nome
Nome, Alaska
-12
IDLW: International Date Line
West
GMT
Civilian Time Zones
Cities
TABLE 4-2: GREENWICH TIME ZONES (GMT)
>
SETUP MENU
Set Cl ock - >
Devicenet - >
Et her net - >