Setting jog count – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 65
49
CHAPTER 4
Configuration
Step 13. Type in the Target Weight you want for this ingredi-
ent.
Step 14. To turn On the Target Proof Limit Switch, click in
the “ON” radio button or to turn off the Target
Proof Limit Switch Click, click in the “Off” radio
button.
Step 15. If you turned the Target Proof Switch ON you need
to set the Gate Time.
Step 16. Double click in the Gate Time field to highlight the
value.
Step 17. Type in the new Gate Time parameter. The Gate
Time parameter is the time it takes for a proof
switch to detect that a Gate Opened or Closed. If
the time to open or close exceeds the Gate Time set-
ting, a gate not open or gate not closed alarm
appears in the front panel of the instrument and on
the Monitor Page of the Web Browser.
Step 18. Double click in the Preact field to highlight the cur-
rent value.
Step 19. Type in the new Preact Value.
Step 20. To turn on the Smart Auto Preact function, click in
the ON radio button.
Step 21. To set the Jog on Time:
•
Double click in the Jog on Time field.
•
Type in the new time parameter.
Step 22. To set the Jog off time:
•
Double click in the Jog off Time field.
•
Type in the new time parameter.
Step 23. To set the Jog count
•
Click on the Jog Count pull down menu.
(See Fig. 4-106)
FIG. 4-106 SETTING JOG COUNT
•
Click on the jog count you want for your
process.
Step 24. Now that you have set all the parameters on this
web page, click on the Enter Parameters button to
set the entries.
Step 25. Click on the right arrow at the bottom of the Web
page to go to the next page of the Adjust Ingredient
setup parameters. (See Fig. 4-107)
FIG. 4-107 ADJUST INGREDIENT 7 PAGE 2
Step 26. Here again the Ingredient Number and the new
ingredient name Four are automatically selected.
Step 27. Double click in the Fill Timer field. Enter the new
Fill Time parameter.
Step 28. Double click in the Wait Timer field. Enter the new
Wait time parameter.
Step 29. Click on the Target Weight “Tolerance” pull down
menu to select Weight or Percentage for the Toler-
ance setting. (See Fig. 4-108) Click on Weight or
Percentage to select the parameter.