Lost ok to dispense alarm/fast dispense, Lost ok to dispense alarm/slow dispense, Fast dispense gate did not open alarm – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 106: Resume dispensing fast display, Fast dispense on, Fast gate did not close

HI-3010 Filler/Dispenser/IBC
90
Service Manual
says LOST OK TO DISPENSE. (See Figs.
7-20 & 7-21)
FIG. 7-20 LOST OK TO DISPENSE ALARM/FAST
DISPENSE
FIG. 7-21 LOST OK TO DISPENSE ALARM/SLOW
DISPENSE
1.
The Operator needs to determine why
the system LOST OK to DISPENSE
by checking for problems with the
electrical and /or mechanical systems.
2.
Once the problem has been fixed,
push the Clear button to clear the
Alarm. The Filler/Dispenser resumes
dispensing from where it stopped.
Fast Gate Did Not Open Alarm
- - - - - ALARM CONDITION - - - - -
•
If the Fast Dispense Gate is not open at the
time you want to dispense, the FAST
GATE DID NOT OPEN alarm appears on
the display. (See Fig. 7-22)
FIG. 7-22 FAST DISPENSE GATE DID NOT OPEN
ALARM
1.
Determine why the Fast Dispense
Gate did not open and correct the
problem.
2.
Press the Clear button to clear the
alarm. The RESUME DISPENS-
ING? display appears. (See Fig. 7-23)
FIG. 7-23 RESUME DISPENSING FAST DISPLAY
•
Press the Start button to resume dispense.
(See Fig. 7-24)
FIG. 7-24 FAST DISPENSE ON
Fast Gate Did Not Close Alarm
- - - - - ALARM CONDITION - - - - -
•
If the Fast Dispense Gate does not close at
the end of a cycle, the FAST GATE DID
NOT CLOSE alarm appears on the dis-
play. (See Fig. 7-25)
FIG. 7-25 FAST GATE DID NOT CLOSE
1.
Determine why the Fast Dispense
Gate did not close and correct the
problem.
2.
Press the Clear button to clear the
alarm. The RESUME DISPENSE?
display appears. (See Fig. 7-26)