IAI America CON-PG User Manual
Page 38

32
5. Operation of CON Controllers
SCON-CA (CON-PT version 1.30 or later), PCON-C, ERC3 (CON-PT version 1.50 or later)
PCON-CFA
Maintenance information screen
Touching [Info Edit] switches the screen to one
where you can edit maintenance information.
• Total number of movements The cumulative total number of actuator movements is shown.
•
•
Total travelled distance The cumulative total distance travelled by the actuator is shown.
The above values can be changed on the maintenance information editing screen.
[Thresholds for Total Number of Movements and Total Travelled Distance]
You can set thresholds for total number of movements and total travelled distance in the parameters specified
below, to cause an alarm to generate when each threshold is exceeded.
e
m
a
N
.
o
N
r
e
t
e
m
a
r
a
P
147
Threshold for total number of movements
148
Threshold for total travelled distance
Message-level alarms
Alarm code
n
o
i
t
p
i
r
c
s
e
D
e
m
a
N
4E
Movements threshold
exceeded
This alarm generates when the total
number of movements exceeds the
threshold set in parameter No. 147.
4F
Travelled distance
threshold exceeded
This alarm generates when the total
travelled distance exceeds the threshold
set in parameter No. 148.
Total fan driving time Shows the total driving time of the fan on the controller