IAI America CON-PG User Manual
Page 190

184
7. Operation of MEC Controllers
4) Setting for push-motion operation (push force, push band)
An example of stopping at 2 points is explained.
In this example, push-motion operation is performed at the start point.
Push force: 50%, Push band: 5.0 mm
No. Operation
Screen
Remarks
1
Touch [Pos. Edit] on the MEC
menu screen.
2
If the password is not “0000,” the
password entry screen appears.
Enter the password.
A desired position setting
password can be set in the
“position data edit password” field
of the parameter edit screen.
3
Touch the value field of position.
When the numeric keypad is
displayed, touch [1], [0], and then
[ENT].
Touch [Starting Point].
Touch [Menu] to return to the MEC
menu screen.
4
Touch the value field of
[PushPower].
When the numeric keypad is
displayed, touch [5], [0], and then
[ENT].
Touch [Menu] to return to the
position setting screen
5
“50” is shown in the push power
field.
Touch [Menu] to return to the
position setting screen
6
Touch the value field of
[PushBand].
When the numeric keypad is
displayed, touch [5] and then
[ENT].
Touch [Menu] to return to the
position setting screen