7. Operation of MEC Controllers

7.5 Initial

Setting

Select whether to stop at 2 points or 3 points.

Touch [Initial Set] on the MEC menu screen.

Before the display switches to the initial setting screen, the password entry screen appears if the
password is other than “0000.”

Enter the password using the numeric keypad, and then
touch [ENT].

The password is “5119” (factory setting).
You can set a desired password using the “system
password” parameter accessible from the maintenance
menu.

If the valid password has been set, the display switches to the initial setting screen.

Stopping at 2 points

Select and touch either [Two Point] or [Three Point]. To
perform positioning operation, select and touch [Pushing
None]. To perform push-motion operation, select and
touch [Pushing].
To stop at 3 points, select [Both OFF] or [Both ON] as the
position specification method.
(Note)

Take note that if push-motion operation is

performed and therefore [Pushing None] is selected, the
completion signal will not be output.
*

If [Pushing None] is selected, LS0 and LS1 (LS2)

will be used as output signals. If [Pushing] is selected, PE0
and PE1 (PE2) will be used as output signals.

Stopping at 3 points

7.6