IAI America CON-PG User Manual
Page 110
104
6. Operation of SEP
Controllers
6.9
Position Setting (Setting of Position-related Data, Jog/Inching Operation)
Position-related data, such as position, push power and push band, are set. You can move the axis
by jogging or inching.
Touch [Pos. Edit] on the SEP menu screen.
If the password is not "0000," the password entry screen appears before changing to the position
setting screen.
Enter a password value from the numeric keypad, and then
touch [ENT].
If the correct password has been entered, the display changes to the screen showing a position
setting list.
The display varies depending on the operation pattern.
Touch the position you want to set.
Touch [Menu] to return to the SEP menu screen.
The screen shown to the left is an example of operation pattern
3.
The settings of various positions are shown.
Number of positions set
Operation pattern
Move
Number of positions set
Standard movement between 2 points: 0
Movement between two points
2
Change travel speed: 1
Movement between two points
2
Change position: 2
Movement between two points
4
Movement by 2 inputs among 3 points: 3
Movement among two points
3
Movement by 3 inputs among 3 points: 4
Movement among two points
3
Continuous back-and-forth operation: 5
Movement between two points
2
You can set a password from "Position edit
password" on the parameter edit screen.
6.10