IAI America CON-PG User Manual
Page 182

176
7. Operation of MEC Controllers
[3] Example of position setting operation
The operation is explained using specific examples.
1) Setting the position, speed, acceleration and deceleration
An example of stopping at 2 points is explained.
Positions are set to operate the actuator back and forth between 10.0 mm and 100.0 mm.
End position: 100.0 mm, Start position: 10.0 mm
No. Operation
Screen
Remarks
1
Touch [Pos. Edit] on the MEC
menu screen.
2
If the password is not “0000,” the
password entry screen appears.
Enter the password.
A desired position setting
password can be set in the
“position data edit” field of the
parameter edit screen.
3
Set the position relating to the
start point, acceleration, and
deceleration.
Touch [Start Point].
Touch [Menu] to return to the MEC
menu screen.
4
Touch the value field of position.
When the numeric keypad is
displayed, touch [1], [0], and then
[ENT].
Touch [Menu] to return to the
position setting screen
5
“10.00” appears next to "Position.”
Touch [Menu] to return to the
position setting screen
䢲䢰䢳䢲
䢲䢰䢳䢲
䢲䢰䢳䢲
䢴䢲䢰䢲䢲
䢳䢲䢰䢲䢲
䢴䢲䢰䢲䢲
䢲䢰䢳䢲
䢲䢰䢳䢲
䢲䢰䢳䢲