[Connections and Settings in Position Control Mode]

Connections and

Settings in Position

Control Mode

PrNo.

Parameter Name

Function/Content

In the case of linear driving, in particular, limit switches should be provided on both
ends of the axis, as illustrated in the figure below, to prevent any mechanical dam-
age due to overshoot of a work, and inhibit driving in the direction in which the
switches operate.


1. When you set Pr04 to 0, and do not connect CCWL/CWL input to COM- (OFF), it
will be judged as abnormality in which limits are simultaneously exceeded in both
CCW and CW directions, and the driver will trip due to “Overtravel input error”.
2. You can set whether to activate a dynamic brake during deceleration when CCW
overtravel inhibit input (CCWL) or CW overtravel inhibit input (CWL) works. For
details, refer to descriptions on Pr66 (Deceleration and stop set-up at overtravel
inhibit input).
3. In some cases, after you turn off the limit switch located above a work on the
vertical axis, a work repeatedly moves up and down since there is no longer upward
torque. In this case, don’t use this function, and carry out limit process on the host
controller side.

The parameter is used to select functions of speed zero clamp input (ZEROSPD)/
torque limit switching (TC) input (connector) CN X5 pin 5.


If you wish to use torque limit switching input, also set Pr5E, Pr63, and Pr70 to 73 all
at once. If settings of Pr70 and Pr73 remain 0, the error No.26 acceleration protec-
tion will occur.

This parameter is to allocate functions of warning output(WARN:CN X5 pin 12).


If you ignore output of warning and continue to use, the motor or driver may fail/be
damaged.

04

06

09

CW Direction

CCW Direction

CCWL

CWL

Work

Servo Motor

Limit

Switch

Limit

Switch

Driver

Standard Default Setup: [ ]

Overtravel Input in-
hibit

ZEROSPD/TC input
selection

Warning output se-
lection

Range of

Settings

Settings

0

[1]

CCWL/

CWLInput

Enabled

Disabled

Input

CCWL

(CN pin X5-8)

CWL

(CN pin X5-7)

Operation

This shows normal state in which the limit

switch on CCW side does not operate.

CCW direction inhibited, and CW direction allowed.

This shows normal state in which the limit

switch on CCW side does not operate.

CCW direction inhibited, and CW direction allowed.

Connection with COM-

Connected

Open

Connected

Open

CCWL and CWL inputs are ignored, and driving is not inhibited (allowed) in
both CCW and CW directions.

Setting

0

[1]

2

Speed Zero Clamp

Disabled

Enabled

Disabled

Torque Limit Switching Input

Disabled
Disabled

Enabled

0 - 1

0 - 2

0 - 6

Remarks

For detailed
information on
functions of
respective outputs
listed in the left, refer
to “Wiring to
Connector CN X5” on
Page 72.

Functions

Output during torque limit
Zero speed detection output
Over-regeneration/overload/fan rotation speed abnormality
Over-regeneration warning output
Overload warning output
To be displayed, but not functioning.
Fan rotation speed abnormality warning output

Setting

0
1

[2]

3
4
5
6