[Preparations]

Preparations

After an Alarm is Cleared (during Servo-ON Command)

Dynamic Brake

Motor Energized

Brake Release
Output (BRK-OFF)

Servo Alarm
Output (ALM)

Alarm Clear
Input (A-CLR)

Approx. 40 ms

120ms or Longer

Cleared

Operation

Release

Energized

Release (ON)

Not Alarm

Not Energized

Operation (OFF)

Alarm

No Input

Input Enabled

Position/Velocity
Command

100ms or Longer

Approx. 10 ms

After an Alarm event (during Servo-ON)

*1. A value of t1 is a value of Pr6B or time needed for decreasing the motor speed to approx. 30 r/min,

whichever is shorter.

*2. For operation of the dynamic brake following an alarm event, also refer to the description in “Sequence at

Alarm” (“Parameter Setting” for every control mode) on Pr68.

Approx. 30r/min

Alarm

Dynamic Brake

Motor Energized

Normal

Energized

Not Alarm

Error

Operation *2

Not Energized

Alarm

1 - 5 ms

t1 *1

Operation (OFF)

Operation (OFF)

Release (ON)

Approx. 30r/min

Release (ON)

A

B

t1 *1

Setting of Pr6B

Setting of Pr6B

Servo Alarm
(ALM)

Brake Release
(BRK-OFF)