Wiring to Connector CN X5

Signal Name

Gain Switching/

Speed Zero Clamp/

Torque Limit

Switching Input

Command Dividing

Multiplier Switching/

Internal Command

Speed Selection 1

Input

CW Overtravel

Inhibit Input

CCW Overtravel

Inhibit Input

• Settings of Pr06 and control mode can change functions.

The control mode can change functions.

• If you open connection with COM- when a moving part of the

machine exceeds the movable range in CW direction, no

torque will be generated in CW direction.

• If you open connection with COM- when a moving part of the

machine exceeds the movable range in CCW direction, no

torque will be generated in CCW direction.

• If you set 1 to Pr04 (Invalid Overtravel Inhibit Input), CWL/

CCWL inputs will be invalid. A default value is invalid (1).

• Setting of Pr66 (DB inaction during driving prohibition) can activate

the dynamic brake when CWL/CCWL input is valid. According to a

default value, the dynamic brake will run (Pr66 is 0).

5

6

7

8

GAIN

/ZEROSPD

/TC

DIV

/INTSPD1

CWL

CCWL

SI

Page 106

SI

Page 106

SI

Page 106

SI

Page 106

Pin No.

Symbol

Function

I/F Circuit

Pr06

0, 1

2

For details on the 2nd gain switching function, refer to Page 138.

Content

Control Mode

Connection with COM-

Open

1st setting value selected. (Pr70,5E,63)

Connected

2nd setting value selected. (Pr71,72,73)

Pr06

0

ZEROSPD input is invalid.

1 [default value]

ZEROSPD input is valid.

Setting of Pr30

Content

0

[default value]

Velocity loop: P1 (proportional/integral) operation

Setting of Pr31

Connection

with COM-

Open

Connected

Velocity loop: P (proportion) operation

1st gain selected (Pr10,11,12,13,14)

1

Open

Connected

2

2nd gain selected (Pr18,19,1A,1B,1C)

When

position

control

Pr02 is

0 or 2

When

internal
velocity

control

Pr02 is 1

The following 2 functions can be used with settings of Pr30.
Gain switching input (GAIN) switches P1/P operation and

first/second gain.

With speed zero clamp input (ZEROSPD), velocity command is

opened when connection with COM- is opened.

You can override this input with Pr06.
A default value of Pr06 is 1, and this input is valid. When

connection with COM- is opened, speed will be zero.

Content

Content

Position
Control/

Internal

Velocity

Control

With torque limit switching input, parameters of acceleration level,
torque limit, excessive position deviation can be switched.

• Input to switch dividing multiply of command pulse

• When this signal is connected to COM-, it will switch a command

dividing multiply numerator from Pr46 (Numerator of 1st command

pulse ratio) to Pr47 (Numerator of 2nd command pulse ratio).

You must not enter any command pulse for 10 ms before or after

switching.

• With internal command speed selection 1 (INTSPD1), four-speed

can be set in combination with INTSPD 2.

• For details on settings of control mode, refer to Page 117.

Position

Control

Internal

Velocity

Control