Installation, Driver, Location – Panasonic MINAS E-series User Manual
Page 18: Environmental conditions how to install
18
Ancillary Screws
(M4 x Length 8 )
The driver and motor should be properly installed to avoid failures, mechanical damages and injuries.
Driver
Location
(1) Indoors, where the driver is not subjected to rain water and direct sun beams. Note that the driver is not a
waterproof structure.
(2) The place where the driver is not exposed to corrosive atmospheres such as hydrogen sulfide, sulfurous acid,
chlorine, ammonia, sulfur, chlorine gas, sulfuric gas, acid, alkali, salt, etc. and is free from splash of flammable
gas, grinding coolant, oil mist, iron powder, chips, etc.
(3) Place in a well-ventilated, and humid-and dust-free space.
(4) Place in a vibration-free space.
Environmental Conditions
How to Install
(1) Parallel type. Install in vertical position. Reserve a drafting
space around the driver for ventilation.
(2) For the mounting dimensions onto the wall face in the board,
refer to Page 193 of the dimensional outline drawing.
Installation
Item
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Vibration
Altitude
Conditions
0 to 55
°C (free from freezing)
Lower than 90%RH (free from condensation)
-20 to 80
°C (free from freezing)
Lower than 90%RH (free from condensation)
Lower than 5.9 m/s
2
(0.6G) at 10 to 60 Hz
Lower than 1000 m
x
1
x
3
x
4
x
5
x
6
STATUS
ALM CODE
Earth connection (M4 screw) tightening
torque shall not exceed 0.39 - 0.59 N•m
Base mount type
(3) Installing to DIN Rail
Install the main body of the driver by using optionally available DV0P3811 (see an “optional” DIN rail mounting unit
on page 190 of Reference edition) and screws (M4 x length 8, pan-head machine screws) supplied with the
option.
DIN rail mounting unit attached to the driver