U2: fault trace – Yaskawa AC Drive P1000 Bypass Technical Manual User Manual
Page 262

No.
(Addr.
Hex)
Name
Description
Analog Output
Level
Unit
U1-18
(61)
oPE Fault Parameter
Displays the parameter number that caused the oPEoo or Err (EEPROM
write error) error.
No signal output
available
–
U1-25
(4D)
Software Number (Flash) FLASH ID
No signal output
available
–
U1-26
(5B)
Software No. (ROM)
ROM ID
No signal output
available
–
U1-75
(851)
Time-Hour/Minute
Displays the current time (Hours and Minutes).
No signal output
available
–
U1-76
(852)
Date – Year
Displays the current year.
No signal output
available
–
U1-77
(853)
Date – Month/Day
Displays the current date (Month and Date).
No signal output
available
–
U1-78
(854)
Date – Week Day
Displays the current date of the week.
0: Sunday
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
No signal output
available
–
<1> The number of decimal places in the parameter value depends on the drive model.
Refer to Defaults by Drive Model on page 275
for details.
<2> When reading the value of this monitor via MEMOBUS/Modbus, a value of 8192 is equal to 100% of the drive rated output current.
<3> Values shown are specific to 208 V bypass drives. Double the value for 480 V bypass drives.
u
U2: Fault Trace
No.
(Addr.
Hex)
Name
Description
Analog Output
Level
Unit
U2-01
(80)
Current Fault
Displays the current fault.
No signal output
available
–
U2-02
(81)
Previous Fault
Displays the previous fault.
No signal output
available
–
U2-03
(82)
Frequency Reference at
Previous Fault
Displays the frequency reference at the previous fault.
No signal output
available
0.01 Hz
U2-04
(83)
Output Frequency at
Previous Fault
Displays the output frequency at the previous fault.
No signal output
available
0.01 Hz
U2-05
(84)
Output Current at Previous
Fault
Displays the output current at the previous fault.
No signal output
available
<1>
<2>
U2-07
(86)
Output Voltage at
Previous Fault
Displays the output voltage at the previous fault.
No signal output
available
0.1 Vac
U2-08
(87)
DC Bus Voltage at
Previous Fault
Displays the DC bus voltage at the previous fault.
No signal output
available
1 Vdc
U2-09
(88)
Output Power at Previous
Fault
Displays the output power at the previous fault.
No signal output
available
0.1 kW
U2-11
(8A)
Input Terminal Status at
Previous Fault
Displays the input terminal status at the previous fault. Displayed as in
U1-10.
No signal output
available
–
U2-12
(8B)
Output Terminal Status at
Previous Fault
Displays the output status at the previous fault. Displays the same status
displayed in U1-11.
No signal output
available
–
U2-13
(8C)
Drive Operation Status at
Previous Fault
Displays the operation status of the drive at the previous fault. Displays the
same status displayed in U1-12.
No signal output
available
–
U2-14
(8D)
Cumulative Operation
Time at Previous Fault
Displays the cumulative operation time at the previous fault.
No signal output
available
1 h
U2-15
(7E0)
Soft Starter Speed
Reference at Previous
Fault
Displays the speed reference for the soft starter at the previous fault.
No signal output
available
0.01 Hz
U2-16
(7E1)
Motor q-Axis Current at
Previous Fault
Displays the q-axis current for the motor at the previous fault.
No signal output
available
0.10%
B.13 U: Monitors
262
YASKAWA SIEP YAIP1B 01A YASKAWA AC Drive – P1000 Bypass Technical Manual