C.4 MEMOBUS/Modbus Setup Parameters

212

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

H5-11: Communications Enter Function Selection

Selects whether an Enter command is necessary to change parameter values via MEMOBUS/Modbus communications.
Refer to

Enter Command on page 229

.

Setting 0: Enter command necessary

Parameter changes become effective after an Enter command. An Enter command must only be sent after the last
parameter change, not for each single parameter.

Setting 1: Enter command not necessary

Parameter value changes become effective immediately without the need to send an Enter command.

No.

Name

Setting Range

Default

H5-11

Communications Enter Function Selection

0 or 1

1