6.4 Cooling Fans

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

145

Per

iodic Ins

pec

tion

&

Maint

ena

nc

e

6

2A0030, 4A0030, 4A0040

Removing the Cooling Fan Finger Guard and Cooling Fan

1.

While pressing in on the hooks located on the left and right sides of the fan finger guard, free the fan finger guard
leading by lifting the back end first.

Figure 6.7

Figure 6.7 Remove the Cooling Fan Finger Guard: 2A0030, 4A0030, 4A0040

2.

Lift out the back end of the fan finger guard first. Unplug the replay connector and free the fan finger guard from
the converter.

Figure 6.8

Figure 6.8 Remove the Cooling Fan: 2A0030, 4A0030, 4A0040

Installing the Cooling Fan

Reverse the procedure described above to reinstall the cooling fan.

1.

Properly connect the fan power lines.

2.

Place the power supply connectors and cable back into the recess of the converter.

Figure 6.9

Figure 6.9 Cooling Fan Power Supply Connectors: 2A0030, 4A0030, 4A0040

A – Back

B – Front

Lift the fan
finger guard
out of the
converter
leading with
the back end.

D1000

A

B

TOEP_C710656_07C_2_0.book 145 ページ 2015年1月9日 金曜日 午後6時23分