D1000, 4 cooling fans – Yaskawa D1000 Series Power Regenerative Converter User Manual
Page 146

6.4 Cooling Fans
146
YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual
3.
Install the replacement fan into the converter.
Figure 6.10
Figure 6.10 Install the Cooling Fan: 2A0030, 4A0030, 4A0040
4.
Tilt up the back end of the fan finger guard and slide the fan finger guard into the opening near the front of the
converter, then guide the fan finger guard into place.
Figure 6.11
Figure 6.11 Reattach the Fan Cover: 2A0030, 4A0030, 4A0040
5.
Press in on the hooks of the left and right sides of the fan cover and guide the fan finger guard until it clicks into
place.
Figure 6.12
Figure 6.12 Reattach the Fan Finger Guard: 2A0030, 4A0030, 4A0040
6.
Turn on the power supply and set o4-03 to 0 to reset the Maintenance Monitor cooling fan operation time.
Insert the fan at an angle so
that it tilts towards the front of
the converter. Next press down
on the back of the fan that still
protrudes from the converter so
that the fan snaps into place.
Insertion area
Front of converter
Back of converter
Fan finger guard
Back of converter
Front of unit
Hook
Hook
Cross-Section
D1000
TOEP_C710656_07C_2_0.book 146 ページ 2015年1月9日 金曜日 午後6時23分