200
YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual
U4-18
(7DAH)
DC BUS Voltage
Reference Source
Selection
Reference
Source
Displays the source for the DC BUS voltage reference as XY-nn.
X: indicates which reference is used:
1 = Reference 1 (b1-01)
Y-nn: indicates the reference source
0-01 = Digital operator
1-01 = Analog (terminal A1)
1-02 = Analog (terminal A2)
1-03 = Analog (terminal A3)
3-01 = MEMOBUS/Modbus communications
4-01 = Communication option card
8-01 = Depends on b1-18
No signal
output
available
–
U4-20
(7DCH)
Option DC
voltage Reference
Option Freq
Ref
Displays the DC bus voltage reference input by an option card (decimal). 0.01%
–
U4-35
(1042H)
Power Supply
Module
Undervoltage
(Uv)
UV Alarm
Axis
Displays the module where power supply Undervoltage (Uv) occurred in
binary.
Note: This setting is available only in model 4A0630.
No signal
output
available
–
U4-36
(1043H)
Power Supply
Module
Overvoltage (ov)
OV Alarm
Axis
Displays the module where power supply Overvoltage (ov) occurred in
binary.
Note: This setting is available only in model 4A0630.
No signal
output
available
–
U4-37
(1044H)
Heatsink
Overheat (oH)
Module
OH Alarm
Axis
Displays the module where Heatsink Overheat (oH) occurred in binary.
Note: This setting is available only in model 4A0630.
No signal
output
available
–
U4-38
(1045H)
Cooling Fan Error
(Fan) Module
FAN Alarm
Axis
Displays the module where Cooling Fan Error (Fan) occurred in binary.
Note: This setting is available only in model 4A0630.
No signal
output
available
–
U6: Operation Status Monitors
U6-80 to
U6-99
(7B0H to
7F9H)
Option Monitors
1 to 20
–
Shows the monitor information for Option Monitor 1 (876 hex) to 20 (8FF
hex).
This information is displayed when option cards are connected.
200 V Class: 100% = 400 Vdc
400 V Class: 100% = 800 Vdc
No signal
output
available
–
U8: Operation Status Monitors
U9-01
(820H)
Electric Power
(GWh)
GWh
Consumed
Shows the total amount of electric power.
0 to 999
1GWh
U9-02
(821H)
Electric Power
(MWh)
MWh
Consumed
0 to 999
1MWh
U9-03
(822H)
Electric Power
(kWh)
kWh
Consumed
0 to 999
1kWh
U9-04
(823H)
Regenerative
Power (GWh)
GWh
Produced
Shows the total amount of regenerated power.
0 to 999
1GWh
U9-05
(824H)
Regenerative
Power (MWh)
MWh
Produced
0 to 999
1MWh
U9-06
(825H)
Regenerative
Power (kWh)
kWh
Produced
0 to 999
1kWh
No.
(Address
Hex)
Name
LCD
Display
Description
Analog
Output
Level
Unit
000 000 000 kWh
U9-03
U9-02
U9-01
000 000 000 kWh
U9-06
U9-05
U9-04
TOEP_C710656_07C_2_0.book 200 ページ 2015年1月9日 金曜日 午後6時23分