Cooling Fan Wiring: 2A0065 to 2A0090
1.
Position the protective tube so the fan connector sits in the center of the protective tube.
2.
Screw down the fan finger guards and the cooling fans to the fan unit base.
3.
Place the connectors between the clamping band bases and the hooks.
Figure 6.17
Figure 6.17 Cooling Fan Wiring: 2A0065, 2A0090
4.
Double-check the relay connector to ensure it is properly connected.
5.
Reattach the cable cover to its original position and tighten the screws so the fan guard holds the cable cover in
place.
Note: Do not pinch the fan cable between parts when reassembling the fan unit.
Figure 6.18
Figure 6.18 Reattaching the cable cover: 2A0065, 2A0090