Yaskawa CIMR-LU Drives User Manual
Page 224

C Standards Compliance
224
YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide
2A0014
R/L1, S/L2, T/L3
10
12 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3
10
14 to 10
–, +1, +2
–
14 to 10
B1, B2
–
14 to 10
10
14 to 10
2A0018
R/L1, S/L2, T/L3
10
12 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3
10
12 to 10
–, +1, +2
–
12 to 10
B1, B2
–
14 to 10
10
12 to 10
2A0025
R/L1, S/L2, T/L3
8
10 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3
8
10 to 6
–, +1, +2
–
10 to 6
B1, B2
–
14 to 10
8
10 to 8
M5
2.0 to 2.5
(17.7 to 22.1)
2A0033
R/L1, S/L2, T/L3
6
8 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3
8
8 to 6
–, +1, +2
–
6
B1, B2
–
12 to 10
8
10 to 8
M5
2.0 to 2.5
(17.7 to 22.1)
2A0047
R/L1, S/L2, T/L3
4
6 to 4
M6
5.4 to 6.0
(47.8 to 53.1)
U/T1, V/T2, W/T3
4
6 to 4
–, +1, +2
–
6 to 4
B1, B2
–
10 to 6
M5
2.7 to 3.0
(23.9 to 26.6)
6
8 to 6
M6
5.4 to 6.0
(47.8 to 53.1)
2A0060
R/L1, S/L2, T/L3
3
4 to 3
M8
9.9 to 11.0
(87.6 to 97.4)
U/T1, V/T2, W/T3
3
4 to 3
–, +1, +2
–
4 to 3
B1, B2
–
8 to 6
M5
2.7 to 3.0
(23.9 to 26.6)
6
6 to 4
M6
5.4 to 6.0
(47.8 to 53.1)
2A0075
R/L1, S/L2, T/L3
2
3 to 2
M8
9.9 to 11.0
(87.6 to 97.4)
U/T1, V/T2, W/T3
2
3 to 2
–, +1, +2
–
3 to 2
B1, B2
–
6
M5
2.7 to 3.0
(23.9 to 26.6)
6
6 to 4
M6
5.4 to 6.0
(47.8 to 53.1)
2A0085
R/L1, S/L2, T/L3
1/0
3 to 1/0
M8
9 to 11
(79.7 to 97.4)
U/T1, V/T2, W/T3
1/0
3 to 1/0
–, +1
–
2 to 1/0
B1, B2
–
6 to 1/0
6
6 to 4
Model
CIMR-LU
Terminal
Recommended
Gauge
AWG, kcmil
Applicable Gauge
AWG, kcmil
Screw
Size
Tightening Torque
N m (lb.in.)