B Parameter Table

184

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

H2: Multi-Function Digital Outputs

No.

Name

Description

Setting

H2-01

Terminals M1-M2
Function Selection (relay)

Refer to

H2 Multi-Function Digital Output Settings on page 184

for a description of

setting values.

Default: 50
Min: 0
Max: 161

H2-02

Terminals M3-M4
Function Selection (relay)

Default: 51
Min: 0
Max: 161

H2-03

Terminals M5-M6
Function Selection (relay)

Default: 6
Min: 0
Max: 161

H2-04

Terminal P1-C1 Function
Selection (photocoupler)

Default: 37
Min: 0
Max: 161

H2-05

Terminal P2-C2 Function
Selection (photocoupler)

Default: F
Min: 0
Max: 161

H2 Multi-Function Digital Output Settings

H2-

Setting

Function

Description

0

During Run

Closed: An Up/Down command is active or voltage is output.

1

Zero Speed

Open: Output speed is greater than the value of E1-09 (Minimum Output Frequency) or S1-01 (Zero
Speed Level at Stop).
Closed: Output frequency is less than or equal to the value of E1-09 (Minimum Output Frequency) or
S1-01 (Zero Speed Level at Stop).

2

Speed Agree 1

Closed: Output speed equals the speed reference (plus or minus the hysteresis set to L4-02).

3

User-set Speed Agree 1

Closed: Output speed and speed reference equal L4-01 (plus or minus the hysteresis set to L4-02).

4

Speed Detection 1

Closed: Output speed is less than or equal to the value in L4-01 with hysteresis determined by L4-02.

5

Speed Detection 2

Closed: Output speed is greater than or equal to the value in L4-01 with hysteresis determined by L4-02.

6

Drive Ready (READY)

Closed: Power up is complete and the drive is ready to accept an Up/Down command.

7

DC Bus Undervoltage

Closed: DC bus voltage is below the Uv trip level set in L2-05.

8

During Baseblock (N.O.)

Closed: Drive has entered the baseblock state (no output voltage).

9

Speed Reference Source

Open: The speed reference is supplied by an external reference (set in b1-01).
Closed: Digital operator supplies the speed reference.

A

Up/Down Command Source

Open: The Up/Down command is supplied by an external reference (set in b1-02).
Closed: Digital operator supplies the Up/Down command.

B

Torque Detection 1

Closed: An overtorque or undertorque situation has been detected.

E

Fault

Closed: Fault occurred. (excluding CPF00 and CPF01)

F

Not used (Through Mode)

Set this value when the terminal is not used or when using the terminal in the pass-through mode.

10

Minor Fault

Closed: An alarm has been triggered, or the IGBTs have reached 90% of their expected life span.

11

Fault Reset Command
Active

Closed: The drive has received a reset command from the multi-function input terminals or from serial
network, or the digital operator’s RESET key has been pressed.

12

Timer Output

Closed: Timer output.

13

Speed Agree 2

Closed: When drive output frequency equals the speed reference ±L4-04.

14

User-set Speed Agree 2

Closed: When the drive output speed is equal to the value in L4-03 ±L4-04.

15

Speed Detection 3

Closed: When the drive output speed is less than or equal to the value in L4-03 ±L4-04.

16

Speed Detection 4

Closed: When the output speed is greater than or equal to the value in L4-03 ±L4-04.

18

Torque Detection 2

Closed: Overtorque or undertorque has been detected.

1A

During Down Direction

Closed: Drive is running in the down direction.

1B

During Baseblock 2 (N.C.)

Open: Drive has entered the baseblock state (no output voltage).

TOEP_C710616_38F_5_0.book 184 ページ 2013年12月4日 水曜日 午前9時56分