Three-phase 600 v class drives, Table 57, A specifications – Yaskawa CIMR-LU Drives User Manual
Page 161

A Specifications
YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide
161
S
p
ec
ifi
c
at
ions
A
◆ Three-Phase 600 V Class Drives
Table 57 Power Ratings (Three-Phase 600 V Class)
<4> Rated motor capacity is calculated with a rated output voltage of 440 V.
<5> Carrier frequency can be set up to 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.
<6> Carrier frequency can be set up to 5 kHz while keeping this current rating. Higher carrier frequency settings require derating.
<7> Carrier frequency can be set up to 2 kHz while keeping this current derating. Higher carrier frequency settings require derating.
Item
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring
connections, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 575 V.
<4> Carrier frequency can be set up to 3 kHz while keeping this current derating. Higher carrier frequency settings require derating.
<5> Carrier frequency can be set up to 8 kHz while keeping this current derating. Higher carrier frequency settings require derating.
<6> Carrier frequency can be set up to 5 kHz while keeping this current derating. Higher carrier frequency settings require derating.
Specification
CIMR-LU5A
0003 0004 0006 0010 0013 0017 0022 0027 0032 0041 0052 0062 0077 0099 0130 0172 0200
Maximum Applicable
Motor Capacity
2
3
5
7.5
10
15
20
25
25-30
40
50-60 50-60
75
100
125
150
250
Input
Input
Current
3.6
5.1
8.3
12
16
23
31
38
33
44
54
66
80
108
129
158
228
Rated
Voltage
Rated
Frequency
Three-phase 500 to 600 Vac 50/60 Hz
Allowable
Voltage
Fluctuation
-10 (-15) to 10%
Allowable
Frequency
Fluctuation
±5%
Input Power
(kVA)
4.1
5.8
9.5
14
18
26
35
43
38
50
62
75
91
123
147
181
261
Output
Rated
Output
Capacity
(kVA)
3.5
4.1
6.3
9.8
12
17
22
27
32
41
52
62
77
99
129
171
199
Rated
Output
Current (A)
3.5
4.1
6.3
9.8
12.5
17
22
27
32
41
52
62
77
99
130
172
200
Overload
Tolerance
150% of rated output current for 60 s
Carrier
Frequency
User adjustable between
2 and 15 kHz
User adjustable between
2 and 10 kHz
User
adjust-
able
between
2 and 8
kHz
User adjustable between
2 and 3 kHz
Maximum
Output
Voltage (V)
Three-phase 500 to 600 Vac (proportional to input voltage)
Maximum
Output
Speed (Hz)
200 Hz (user-adjustable)
TOEP_C710616_38F_5_0.book 161 ページ 2013年12月4日 水曜日 午前9時56分