beautypg.com

U: monitors, U: monitors on, U1: operation status monitors – Yaskawa CIMR-LU Drives User Manual

Page 206

background image

B Parameter Table

206

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

U: Monitors

Monitor parameters allow the user to view drive status, fault information, and other data concerning drive operation.

U1: Operation Status Monitors

T2-19

<44>

Rotation Direction for
Auto-Tuning of PG-E3
Encoder Characteristics

Sets the direction of motor rotation for execution of Auto-Tuning of PG-E3 encoder
characteristics (T2-01 = 12).
0: Forward (Up)
1: Reverse (Down)

Default: 0
Min: 0
Max: 1

<4> Default setting value varies by the drive model (o2-04).

<9> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive. Multiply value by 2.875 for 600 V class drives.

<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU2A0008 to 2A0033, 4A0005 to 4A0018, and 5A0003

to 5A0013 display values in 0.01 A units, while models CIMR-LU2A0047 to 2A0415, 4A0024 to 4A0605, and 5A0017 to 5A0200 display

values in 0.1 A units.

<30> Setting units are determined by the induced voltage constant unit selection for PM motors set to T2-13.

<43> When PG-E3 option connected: Max setting = 48

<44> Available in drive software versions PRG: 7017 or later.

No.

Name

Description

Analog Output

Level

Unit

U1-01

Speed Reference

Monitors the speed reference.

10 V:
Max frequency
(-10 to +10 V)

0.01%

<29>

U1-02

Output Speed

Displays the output speed.

10 V:
Max frequency
(-10 to +10 V)

0.01%

<29>

U1-03

Output Current

Displays the output current.

10 V: Drive
rated current

<10> <40>

U1-04

Control Method

0: V/f Control
2: Open Loop Vector Control
3: Closed Loop Vector Control
7: Closed Loop Vector Control for PM

No signal output
available

U1-05

Speed Feedback

Displays the motor speed feedback.

10 V:
Max Frequency
(-10 to +10 V)

0.01%

<29>

U1-06

Output Voltage
Reference

Displays the output voltage.

10 V:
200 Vrms

<9>

0.1 Vac

U1-07

DC Bus Voltage

Displays the DC bus voltage.

10 V: 400 V

<9>

1 Vdc

U1-08

Output Power

Displays the output power (this value is calculated internally).

10 V: Drive
rated power
(kW)
(-10 to +10 V)

<12>

U1-09

Torque Reference

Monitors the internal torque reference.

10 V: Motor
rated torque
(-10 to +10 V)

0.1%

No.

Name

Description

Setting

TOEP_C710616_38F_5_0.book 206 ページ 2013年12月5日 木曜日 午前11時22分