5 Troubleshooting

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

139

Tr

ou

blesh

oot

ing

5

Copy Function Related Displays

Tasks, Errors, and Troubleshooting

The table below lists the messages and errors that may appear when using the Copy function.

When executing the tasks offered by the Copy function, the operator will indicate the task being performed. When an
error occurs, a code appears on the operator to indicate the error. Note that errors related to the Copy function do not
trigger a multi-function output terminal that has been set up to close when a fault or alarm occurs. To clear an error,
simply press any key on the operator and the error display will disappear.

Table 39

lists the corrective action that can be taken when an error occurs.

Note: 1. Whenever using the copy function, the drive should be fully stopped.

2. The drive will not accept an Up/Down command while the Copy function is being executed.
3. Parameters can only be saved to a drive when the voltage class, capacity, control mode, and software version match.

Table 39 Copy Function Task and Error Displays

Digital Operator Display

Task

CoPy

Writing Parameter Settings (flashing)

CPEr

Control Mode Mismatch

CPyE

Error Writing Data

CSEr

Copy Unit Error

dFPS

Drive Model Mismatch

ECE

Copy Error

ECS

Checksum Error

EdE

Write Impossible

EiF

Write Data Error

End

Task Complete

EPE

ID Mismatch

ErE

Data Error

EvE

Verify Error

iFEr

Communication Error

ndAT

Model, Voltage Class, Capacity Mismatch

rdEr

Error Reading Data

rEAd

Reading Parameter Settings (flashing)

vAEr

Voltage Class, Capacity Mismatch

vFyE

Parameter settings in the drive and those saved to the copy function are not the same

vrFy

Comparing Parameter Settings (flashing)