B Parameter Table

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

185

Par

ame

te

r Ta

ble

B

1C

Motor 2 Selection

Open: Motor 1 is selected
Closed: Motor 2 is selected

1D

During Regeneration

Closed: Motor is operated in regenerative mode.

1E

Reset Enabled

Closed: An automatic reset is performed

1F

Motor Overload Alarm
(oL1)

Closed: oL1 is at 90% of its trip point or greater. An oH3 situation also triggers this alarm.

20

Drive Overheat Pre-alarm
(oH)

Closed: Heatsink temperature exceeds the parameter L8-02 value.

2F

Maintenance Period

Closed: Cooling fan, electrolytic capacitors, IGBTs, or the soft charge bypass relay may require
maintenance.

30

During Torque Limit

Closed: When the torque limit has been reached.

33

Within Position Lock
Bandwidth

Closed: Position deviation is within the Position Lock Bandwidth.

37

During Frequency Output

Open: No frequency output from drive when stopped with baseblock, stopped with DC injection braking
during initial excitation, or stopped with short circuit braking.
Closed: Drive is outputting a frequency.

47

Input Phase Loss

Closed: Input phase loss has occurred
Open: Normal operation (no phase loss detected)

4E

Braking Transistor Fault (rr)

Closed: The built-in dynamic braking transistor failed.
Note: This function is not available in models CIMR-LU2A0145 to 2A0415, 4A0075 to 4A0216, or
5A0052 to 5A0200.

50

Brake Control

Close: Release brake
Open: Apply brake

51

Output Contactor Control

Closed: Close output contactor

52

Door Zone Reached

Closed: Indicates that the door zone has been reached.

53

Not Zero Speed

Closed: Speed is greater than the zero speed level set to S1-01
Open: Operating at zero speed level

54

Light Load Direction

Closed: Light load direction is up
Open: Light load direction is down

55

Light Load Direction
Detection Status

Closed: Ready for Light Load Direction Search
Open: Light Load Detection in progress

58

Safe Disable Status

Closed: Safe Disable terminals H1-HC and H2-HC are open, drive is in a baseblock state
Open: Safe Disable terminals H1-HC and H2-HC are closed (normal operation)

5C

<44>

Motor Current Monitor

Open: Output current is greater than the value of L8-99.
Closed: Output current is less than or equal to the value of L8-99.

60

Internal Cooling Fan Alarm

Closed: Internal cooling fan alarm

61

Motor Pole Search Status

Closed: Motor pole search successful

100 to 161

Function 0 to 61 with Inverse
Output

Inverts the output switching of the multi-function output functions.
Sets the last two digits of 1

to reverse the output signal of that specific function.

<44> Available in drive software versions PRG: 7017 or later.

H2 Multi-Function Digital Output Settings