O: operator related parameters, O1: digital operator display selection – Yaskawa CIMR-LU Drives User Manual
Page 196
![background image](https://www.manualsdir.com/files/819676/content/doc196.png)
B Parameter Table
196
YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide
◆ o: Operator Related Parameters
The o parameters set up the digital operator displays.
■
o1: Digital Operator Display Selection
No.
Name
Description
Setting
o1-01
Drive Mode Unit Monitor
Selection
Switches the display after the power has been turned on. When using an LED
operator, pressing the up arrow key will display the following data: frequency
reference
→ rotational direction → output frequency → output current → output
voltage
→ U1-
.
(This is done by entering the 1
part of U1-
. Certain monitors are not available
in some control modes.)
Default: 106
(Monitor U1-06)
Min: 105
Max: 699
o1-02
User Monitor Selection
after Power Up
o1-02 selects the information that is displayed when the power is turned on.
1: Speed reference (U1-01)
2: Direction
3: Output speed (U1-02)
4: Output current (U1-03)
5: User-selected monitor (set by o1-01)
Default: 1
Min: 1
Max: 5
o1-03
Digital Operator Display
Unit Selection
Sets the units the drive should use to display the frequency reference and motor speed
monitors.
0: 0.01 Hz
1: 0.01% (100% = E1-04)
2: r/min (calculated using the number of motor poles setting in E2-04, E4-04, or E5-
04)
3: User-selected units (set by o1-10 and o1-11)
4: Elevator units 1 (speed in m/s, accel/decel rate and jerk in s)
5: Elevator units 2 (speed in m/s, accel/decel rate in m/s
2
, jerk in m/s
3
)
6: Elevator units 3 (speed in ft/min, accel/decel rate in ft/s
2
, jerk in ft/s
3
)
Default: 1
Min: 0
Max: 6
o1-04
V/f Pattern Setting Units
0: Hz
1: r/min
Min: 0
Max: 1
o1-05
LCD Contrast Control
Sets the brightness of the LCD operator (option).
Default: 3
Min: 0
Max: 5
o1-06
User Monitor Selection
Mode
0: 3 Monitor Sequential (Displays the next 2 sequential monitors)
1: 3 Monitor Selectable (o1-07 and o1-08 selected monitor is displayed)
Default: 0
Min: 0
Max: 1
o1-07
Second Line Monitor
Selection
Selects the monitor displayed on the second line.
Default: 102
Min: 101
Max: 699
o1-08
Third Line Monitor
Selection
Selects the monitor displayed on the third line.
Default: 103
Min: 101
Max: 699
o1-10
User-Set Display Units
Maximum Value
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output frequency.
o1-11 sets the position of the decimal position.
Min: 1
Max: 60000
o1-11
User-Set Display Units
Decimal Display
Min: 0
Max: 3
o1-12
Length Units
0: Millimeter unit
1: Inch unit
Default: 0
Min: 0
Max: 1
o1-20
Traction Sheave Diameter Sets the traction sheave diameter for display unit calculations.
Default:
400 mm
Min: 100 mm
Max:
2000 mm