beautypg.com

Currents, C6: carrier frequency – Yaskawa CIMR-LU Drives User Manual

Page 171

background image

B Parameter Table

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

171

Par

ame

te

r Ta

ble

B

C6: Carrier Frequency

C5-18

Load Inertia Ratio

Sets the ratio between the motor and load inertia.

Default: 1.0
Min: 0.0
Max: 6000.0

C5-19

Speed Control Loop
Proportional Gain Time
during Position Lock

Sets the Speed Control Loop Proportional gain used during Position Lock.

Default:

<5>

Min: 0.00
Max: 300.00

C5-20

Speed Control Loop
Integral Time during
Position Lock

Sets the Speed Control Loop Integral time used during Position Lock.

Default:0.100 s
Min: 0.000 s
Max: 10.000 s

C5-50

<45>

Set Vibrational Frequency
Filter

Sets the mechanical vibration filter frequency in units of 1 Hz.
Note: Set C5-50 to 0 (Hz) to disable the filter. The frequencies from 1 to 19 Hz cannot
be set. Test equipment may be required to determine the mechanical resonance
frequency. Setting C5-50 to an improper frequency will result in ineffective filtering
of the effects of mechanical resonance.

Default: 0 Hz
Min: 20 Hz
Max: 1000 Hz

<4> Default setting value varies by the drive model (o2-04).

<5> Default setting is determined by the control mode (A1-02).

<45> Available in drive software versions PRG: 7200 or later.

No.

Name

Description

Setting

C6-03

<4> Default setting value varies by the drive model (o2-04).

<39> Available in drive software versions PRG: 7016 or later.

Carrier Frequency

Sets the carrier frequency.

Default:

<4>

Min: 1.0 kHz
Max: 15.0 kHz

C6-06

PWM Method

Selects PWM modulation method.
0: 2-phase/3-phase conversion
1: 2-phase modulation
2: 3-phase modulation

Default: 0
Min: 0
Max: 2

C6-09

Carrier Frequency during
Rotational Auto-Tuning

0: Carrier Frequency = 5 kHz
1: Setting value for C6-03

Default: 0
Min: 0
Max: 1

C6-21

Inspection Operation
Carrier Frequency

Sets the carrier frequency during Inspection Run.
0: Setting value for C6-03
1: Carrier Frequency = 2 kHz

Default: 1
Min: 0
Max: 1

C6-23

Carrier Frequency during
Initial Motor Pole Search

Sets the carrier frequency when estimating the initial polarity.
0: Carrier Frequency = 2 kHz
1: Setting value for C6-03

Default: 0
Min: 0
Max: 1

C6-31

<39>

Carrier Frequency during
Rescue Operation

Sets the carrier frequency during Rescue Operation.
0: C6-03 setting
1: 2 kHz

Default: 0
Min: 0
Max: 1

No.

Name

Description

Setting

TOEP_C710616_38F_5_0.book 171 ページ 2013年12月4日 水曜日 午前9時56分