Yaskawa CIMR-LU Drives User Manual
Page 183
![background image](https://www.manualsdir.com/files/819676/content/doc183.png)
B Parameter Table
YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide
183
Par
ame
te
r Ta
ble
B
1A
Accel/decel Ramp Selection 2
Used in conjunction with an input terminal set for “Accel/decel ramp selection 1” (H1-
= 7), and
allows the drive to switch between accel/decel ramp 3 and 4.
20 to 2F
External Fault
20: N.O., Always detected, ramp to stop
21: N.C., Always detected, ramp to stop
22: N.O., During run, ramp to stop
23: N.C., During run, ramp to stop
24: N.O., Always detected, coast to stop
25: N.C., Always detected, coast to stop
26: N.O., During run, coast to stop
27: N.C., During run, coast to stop
28: N.O., Always detected, Fast Stop
29: N.C., Always detected, Fast Stop
2A: N.O., During run, Fast Stop
2B: N.C., During run, Fast Stop
2C: N.O., Always detected, alarm only (continue running)
2D: N.C., Always detected, alarm only (continue running)
2E: N.O., During run, alarm only (continue running)
2F: N.C., During run, alarm only (continue running)
50
Nominal Speed
Closed: Activates the nominal speed (d1-19).
51
Intermediate Speed
Closed: Activates the Intermediate Speed (d1-20).
52
Releveling Speed
Closed: Activates the Releveling Speed (d1-23).
53
Leveling Speed
Closed: Activates the Leveling Speed (d1-26).
54
Inspection Operation
Closed: Activates Inspection operation using the speed set in d1-24.
55
Rescue Operation
Closed: Activates rescue operation.
56
Motor Contactor Feedback
Open: Motor contactor open
Closed: Motor contactor closed (N.O.)
57
High Speed Limit (Up)
Closed: Uses the leveling speed as the maximum speed when going up.
58
High Speed Limit (Down)
Closed: Uses the leveling speed as the maximum speed when going down.
5A
Motor Contactor Feedback 2
Open: Motor contactor closed (N.C.)
Closed: Motor contactor open
5B
Brake Feedback 2
Open: Brake open (N.C.)
Closed: Brake closed
5C
Floor Sensor
Closed: Initiate Direct Landing (S5-10 = 1)
67
Communications Test Mode
Tests the MEMOBUS/Modbus RS-485/422 interface. Displays “PASS” if the test completes
successfully.
79
Brake Feedback
Open: Brake closed
Closed: Brake open (N.O.)
<44> Available in drive software versions PRG: 7017 or later.
H1 Multi-Function Digital Input Settings
H1-
Setting
Function
Description