B Parameter Table

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

207

Par

ame

te

r Ta

ble

B

U1-10

Input Terminal Status

Displays the input terminal status.

No signal output
available

U1-11

Output Terminal Status

Displays the output terminal status.

No signal output
available

U1-12

Drive Status

Displays the drive operation status.

No signal output
available

U1-13

Terminal A1 Input
Voltage

Displays the voltage input to terminal A1.

10 V: 100%
(-10 to +10 V)

0.1%

U1-14

Terminal A2 Input
Voltage

Displays the voltage input to terminal A2.

10 V: 100%
(-10 to +10 V)

0.1%

U1-16

Output Speed after Soft
Start

Displays output speed with ramp time and jerk settings. Units determined by o1-
03.

10 V:
Max frequency
(-10 to +10 V)

0.01%

<29>

U1-17

DI-A3 Option Card
Input Status

Displays the reference value input from the DI-A3 option card.
Display will appear in hexadecimal as determined by the digital card input
selection in F3-01.
3FFFF: Set (1 bit) + sign (1 bit) + 16 bit

No signal output
available

No.

Name

Description

Analog Output

Level

Unit

U1 - 10= 00000000

Digital input 1
(terminal S1 enabled)
Digital input 2
(terminal S2 enabled)
Digital input 3
(terminal S3 enabled)
Digital input 4
(terminal S4 enabled)
Digital input 5
(terminal S5 enabled)
Digital input 6
(terminal S6 enabled)
Digital input 7
(terminal S7 enabled)
Digital input 8
(terminal S8 enabled)

1

1

1

1

1

1

1

1

YEA_co
mmon

U1 - 11= 00000000

Multi-Function
Digital Output
(terminal M1-M2)

Digital Output
(terminal M3-M4)

Digital Output
(terminal M5-M6)

Multi-Function

Multi-Function

Digital Output
(terminal P1-C1)

Multi-Function

Digital Output
(terminal P2-C2)

Multi-Function

Not Used

Fault Relay
(terminal MA-MC closed

MA-MC open)

1

1

1

1

1

1

YEA_co
mmon

U1 - 12= 00000000

During run

During zero-speed

During down direction

During fault reset
signal input

During speed agree

Drive ready

During alarm
detection

During fault detection

1
1

1
1

1
1

1

1

YEAco
mmon

TOEP_C710616_38F_5_0.book 207 ページ 2013年12月4日 水曜日 午前9時56分