beautypg.com

Yaskawa CIMR-LU Drives User Manual

Page 218

background image

C Standards Compliance

218

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

Table 60 Fuses and Fuse Holders

Guarding Against Harmful Materials

When installing IP00 enclosure drives, use an enclosure that prevents foreign material from entering the drive from above
or below.

Drive Model

CIMR-LU

<1> DC is not available for UL standards.

<2> Manufacturer does not recommend a specific fuse holder for this fuse. Contact Yaskawa or your nearest sales representative on fuse

dimensions.

DC Power Supply Input

<1>

Drive Model

CIMR-LU

DC Power Supply Input

<1>

Fuse

Fuse Holder

Fuse

Fuse Holder

Type

Rated

Short-

circuit

Breaking

Current

(kA)

Qty.

Type

Qty.

Type

Rated

Short-

circuit

Breaking

Current

(kA)

Qty.

Type

Qty.

200 V Class

400 V Class

2A0008

CR2LS-50

100

2

CM-1A

1

4A0005

CR6L-50

100

2

CMS-4

2

2A0011

4A0006

2A0014

CR2LS-75

4A0007

2A0018

CR2LS-100

4A0009

2A0025

CR2L-125

2

CM-2A

1

4A0015

CR6L-75

2

CMS-5

2

2A0033

CR2L-150

4A0018

2A0047

CR2L-175

4A0024

CR6L-100

2A0060

CR2L-225

2

<2>

4A0031

CR6L-150

2A0075

CR2L-260

4A0039

2A0085

CR2L-300

4A0045

CR6L-200

2

<2>

2A0115

CR2L-350

4A0060

CR6L-250

2A0145

CR2L-400

4A0075

2A0180

CR2L-450

4A0091

CR6L-300

2A0215

CR2L-600

4A0112

CR6L-350

2A0283

4A0150

CR6L-400

2A0346

CS5F-800

200

4A0180

CS5F-600

200

2A0415

CS5F-1200

4A0216
4A0260

4A0304

CS5F-800

200

2

<2>

4A0370
4A0450

CS5F-1200

4A0605

CS5F-1500

TOEP_C710616_38F_5_0.book 218 ページ 2013年12月4日 水曜日 午前9時56分