T: Motor Tuning

Enter data into the following parameters to tune the motor and drive for optimal performance.

T1: Induction Motor Auto-Tuning

No.

Name

Description

Setting

T1-01

<4> Default setting value varies by the drive model (o2-04).

<5> Default setting is determined by the control mode (A1-02).

<9> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive. Multiply value by 2.875 for 600 V class drives.

<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU2A0008 to 2A0033, 4A0005 to 4A0018, and 5A0003

to 5A0013 display values in 0.01 A units, while models CIMR-LU2A0047 to 2A0415, 4A0024 to 4A0605, and 5A0017 to 5A0200 display

values in 0.1 A units.

<18> The variety of Auto-Tuning methods depends on the control mode setting. V/f Control allows T1-01 to be set to 2 or 3, while vector control

modes (OLV and CLV) allow T1-01 to be set to 0 through 4.

Auto-Tuning Mode
Selection

0: Rotational Auto-Tuning
1: Stationary Auto-Tuning 1
2: Stationary Auto-Tuning for Line-to-Line Resistance
4: Stationary Auto-Tuning 2

Default: 0

<5>

Min: 0
Max: 4

<18>

T1-02

Motor Rated Power

Sets the motor rated power as specified on the motor nameplate.
Note: Use the following formula to convert horsepower into kilowatts: kW = HP

×

0.746.

Default:

<4>

Min: 0.00 kW
Max: 650.00 kW

T1-03

Motor Rated Voltage

Sets the motor rated voltage as specified on the motor nameplate.

Default:
200.0 V

<9>

Min: 0.0 V
Max: 255.0 V

<9>

T1-04

Motor Rated Current

Sets the motor rated current as specified on the motor nameplate.

Default:

<4>

Min: 10% of drive
rated current
Max: 200% of
drive rated
current

<10>

T1-05

Motor Base Frequency

Sets the rated frequency of the motor as specified on the motor nameplate.

Default: 50.0 Hz
Min: 0.0 Hz
Max: 200.0 Hz

T1-06

Number of Motor Poles

Sets the number of motor poles as specified on the motor nameplate.

Default: 4
Min: 2
Max: 48

T1-07

Motor Base Speed

Sets the rated speed of the motor as specified on the motor nameplate.

Default:
1450 r/min
Min: 0 r/min
Max: 24000 r/min

T1-08

Encoder Resolution (pulses
per revolution)

Set the number of pulses per revolution for the PG being used (pulse generator or
encoder).

Default: 1024 ppr
Min: 0 ppr
Max: 60000 ppr

T1-09

Motor No-Load Current
(Stationary Auto-Tuning 1
and 2)

Sets the no-load current for the motor.
After setting the motor capacity to T1-02 and the motor rated current to T1-04, this
parameter will automatically display the no-load current for a standard 4 pole
Yaskawa motor. Enter the no-load current as indicated on the motor test report.

Default: –
Min: 0 A
Max:
Up to T1-04

<10>

T1-10

Motor Rated Slip
(Stationary Auto-Tuning 2)

Sets the motor rated slip.
After setting the motor capacity to T1-02, this parameter will automatically display
the motor slip for a standard 4 pole Yaskawa motor. Enter the motor slip as indicated
on the motor test report.

Default: –
Min: 0.00 Hz
Max: 20.00 Hz