Crimp Terminals
Yaskawa recommends using CRIMPFOX 6 by Phoenix Contact or equivalent crimp terminals with the specifications
listed in
for wiring to ensure proper connections.
Note: Properly trim wire ends so loose wire ends do not extend from the crimp terminals.
Table 54 Crimp Terminal Sizes
6.
Route the option wiring.
Depending on the drive model, some drives may require routing the wiring through the side of the front cover to
the outside. For drive models CIMR-LU2A0008 through 2A0033, 4A0005 through 4A0018, and 5A0003 through
5A0010, cut out the perforated openings on the left side of the drive front cover as shown in
-A and
leave no sharp edges to damage wiring.
Route the wiring inside the enclosure as shown in
-B for drive models CIMR-LU2A0047 through
2A0415, 4A0024 through 4A0605, and 5A0013 through 5A0200 that do not require routing through the front
cover.
Figure 88
Figure 97 Wire Routing Examples
Wire Gauge
mm
2
Phoenix Contact Model
L
mm (in)
d1
mm (in)
d2
mm (in)
0.25 (24 AWG)
AI 0.25 - 6YE
10.5 (13/32)
0.8 (1/32)
2 (5/64)
0.34 (22 AWG)
AI 0.34 - 6TQ
10.5 (13/32)
0.8 (1/32)
2 (5/64)
0.5 (20 AWG)
AI 0.5 - 6WH
14 (9/16)
1.1 (3/64)
2.5 (3/32)
A – Route wires through the openings
provided on the left side of the
front cover.
(CIMR-LU2A0008 through 2A0033,
4A0005 through 4A0018, and
5A0003 through 5A0010)
<1> The drive will not meet NEMA Type 1 requirements if wiring is exposed outside the enclosure.
B – Use the open space provided
inside the drive to route option
wiring.
(CIMR-LU2A0047 through 2A0415,
4A0024 through 4A0605, and
5A0013 through 5A0200)
d1
d2
6 mm
(0.24 in.)
L
B
A