S6-10: Overacceleration Detection Level

If the elevator car accelerates at an abnormal rate, the drive triggers an overacceleration fault (dv6) and the motor coasts
to stop. Parameter S6-10 determines the acceleration rate that triggers the dv6 fault. A setting of 0.0 m/s

2

disables

overacceleration detection.

S6-11: Overacceleration Detection Time

Sets the time that the acceleration must exceed the overacceleration detection level before as fault is triggered.

S6-12: Overacceleration Detection Selection

Determines the conditions for detecting an overacceleration situation.

Setting 0: Always enabled
Setting 1: During run only

S6-15: Speed Reference Loss Detection

Enabled or disables detection for missing speed reference (FrL).

Setting 0: Disabled
Setting 1: Enabled

S6-16: Restart after Baseblock Selection

Allows the drive to restart the motor after returning to normal operation from Baseblock state (H1-

= 8/9) or from

Safe Torque-Off state (Safe Disable inputs H1 and H2 enabled) while the Up/Down command is still active.

Setting 0: No restart after Baseblock or Safe Torque-Off

Do not restart the motor when leaving the Baseblock or Safe Torque-Off state even if an Up/Down command is still
active.

Setting 1: Restart after Baseblock or Safe Torque-Off

Restart when the Up/Down command is still active while the Baseblock or Safe Torque-Off state is left. To use this
function with the Safe Disable function, parameter L8-88 must be set to 1.

No.

<1> Default setting is determined by parameter o1-03. If o1-03 is set to 0 through 5, the default is 1.5 m/s2. If o1-03 is set to 6, the default is 5.0 ft/

s

2

(setting range: 0.0 to 50.0 ft/s

2

).

Parameter Name

Setting Range

Default

S6-10

Overacceleration Detection Level

0.0 to 20.0 m/s

2

1.5 m/s

2

<1>

No.

Parameter Name

Setting Range

Default

S6-11

Overacceleration Detection Time

0 to 5000 ms

50 ms

No.

Parameter Name

Setting Range

Default

S6-12

Overacceleration Detection Selection

0 or 1

0

No.

Parameter Name

Setting Range

Default

S6-15

Speed Reference Loss Detection

0 or 1

1

No.

Parameter Name

Setting Range

Default

S6-16

Restart after Baseblock Selection

0 or 1

0