E5: pm motor settings, B parameter table – Yaskawa CIMR-LU Drives User Manual
Page 177
![background image](https://www.manualsdir.com/files/819676/content/doc177.png)
B Parameter Table
YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide
177
Par
ame
te
r Ta
ble
B
■
E5: PM Motor Settings
No.
Name
Description
Setting
E5-02
<1> Parameter setting value is not reset to the default value when the drive is initialized.
<4> Default setting value is determined by the drive model (o2-04).
<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU2A0008 to 2A0033, 4A0005 to 4A0018, and 5A0003
to 5A0013 display values in 0.01 A units, while models CIMR-LU2A0047 to 2A0415, 4A0024 to 4A0605, and 5A0017 to 5A0200 display
values in 0.1 A units.
<43> When PG-E3 option connected: Max setting = 48
Motor Rated Power
Sets the rated capacity of the motor.
Default:
Min: 0.10 kW
Max: 650.00 kW
E5-03
Motor Rated Current
Sets the motor rated current.
Default:
Min: 10% of drive
rated current
Max: 200% of
drive rated
current
E5-04
Number of Motor Poles
Sets the number of motor poles.
Default: 12
Min: 2
Max: 120
E5-05
Motor Stator Resistance
(Single Phase)
Sets the stator resistance (1 phase value).
Default:
Min: 0.000
Ω
Max: 65.000
Ω
E5-06
Motor d-Axis Inductance
Sets the d-axis inductance.
Default:
Min: 0.00 mH
Max: 600.00 mH
E5-07
Motor q-Axis Inductance
Sets the q-axis inductance.
Default:
Min: 0.00 mH
Max: 600.00 mH
E5-09
Motor Induction Voltage
Constant 1
Sets the induced phase peak voltage in units of 0.1 mV (rad/s) [electrical angle].
When setting this parameter, E5-24 should be set to 0.0.
Default:
Min:
0.0 mV/(rad/s)
Max:
6500.0 mV/(rad/s)
E5-11
Encoder Offset
Sets the offset between the rotor magnetic axis and the encoder zero position. Set
during Encoder Offset Tuning.
Default: 0.0 deg
Min: -180 deg
Max: 180 deg
E5-24
Motor Induction Voltage
Constant 2
Sets the induced phase-to-phase rms voltage in units of 0.1 mV/(r/min) [mechanical
angle].
When setting this parameter, E5-09 should be set to 0.0.
Default:
0.0 mV/(r/min)
Min:
0.0 mV/(r/min)
Max:
6500.0 mV/(r/min)
TOEP_C710616_38F_5_0.book 177 ページ 2013年12月4日 水曜日 午前9時56分