Yea_common, 4 start-up programming & operation, Following the wiring diagram show in figure 60 – Yaskawa CIMR-LU Drives User Manual
Page 119: Starting rescue operation 1, Ending rescue operation 1
![background image](https://www.manualsdir.com/files/819676/content/doc119.png)
4 Start-Up Programming & Operation
YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide
119
S
tart-U
p
Prog
rammin
g
&
Op
er
at
io
n
4
Using a Single Battery with Minimum 250 Vdc (500 Vdc, 720 Vdc)
Follow the instructions when using one battery to supply both, main circuit and controller. The battery voltage must be at
least 250 Vdc for 200 V class drives, 500 Vdc for 400 V class drives, or 720 Vdc for 600 V class drives.
Wiring
Following the wiring diagram show in
Figure 53
Figure 60 Using a Backup Battery With Minimum 250 Vdc (500 Vdc, 720 Vdc)
Operation Sequence
Starting Rescue Operation
1.
Open contactor B.
2.
Set the input terminal programmed for Rescue Operation (H1-
= 55).
3.
Close contactor A.
4.
Set the Up/Down command.
Ending Rescue Operation
1.
After the car has stopped, open contactor A.
2.
Clear the input terminal set for Rescue Operation (H1-
= 55).
3.
Close contactor B to return to operation with normal power supply.
-
S
3
to S
8
L1000A
DC bus power supply
L1
L2
L3
CN19
1
4
W/T3
V/T2
U/T1
R/L1
S/L2
T/L3
B1
B2
SC
H1-
غغ = 55
(Rescue Operation)
Battery for DC bus
200 V Class: 250 to 340 Vdc
400 V Class: 500 to 680 Vdc
600 V Class: 720 to 850 Vdc
Magnetic Contactor A
Magnetic Contactor B
Control
circuit
Power supply
Magnetic Contactor Sequence
H1-
غغ = 55
(Rescue Operation)
Magnetic Contactor B
Magnetic Contactor A
YEA_common
TOEP_C710616_38F_5_0.book 119 ページ 2013年12月4日 水曜日 午前9時56分