beautypg.com

7 option card installation, Prior to installing the option, 7option card installation – Yaskawa CIMR-LU Drives User Manual

Page 148: Yea_common

background image

148

YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide

7 Option Card Installation

7

Option Card Installation

This section provides instructions on installing the option cards listed in

Table 45

.

Prior to Installing the Option

Prior to installing the option, wire the drive, make the necessary connections to the drive terminals, and verify that the
drive functions normally. Refer to the

Table 45

for information on wiring and connecting the drive.

Table 45

below lists the number of option cards that can be connected to the drive and the drive connectors for connecting

those option cards.

Table 45 Option Card Installation

Figure 85

shows an exploded view of the drive with the option and related components for reference.

Figure 78

Figure 85 Installing an Option Card

Option Card

<1> If two PG option cards are connected, use both CN5-B and CN5-C. If only one PG option card is connected to the drive, use the CN5-C

connector.

<2> These option cards are not available for the application with Motor 2 Selection.

<3> When DI-A3 is to be used as monitors, the card can be connected to any of CN5-A, CN5-B or CN5-C. The input status of DI-A3 can

then be viewed using U1-17.

Connector

Number of Cards Possible

PG-B3, PG-X3

CN5-C

2

<1>

PG-F3

<2>

, PG-E3

CN5-C

1

DO-A3, AO-A3

CN5-A, B, C

1

SI-S3, DI-A3

<3>

CN5-A

1

A – Insertion point for CN5

G – Removable tabs for wire routing

B – Option card

H – Ground wire

C – Included screws

I – Drive grounding terminal (FE)

D – Front cover

J – Connector CN5-A

E – Digital operator

K – Connector CN5-B

F – Terminal cover

L – Connector CN5-C

G

A

B

C

H

D

E

F

I

J

K

L

YEA_common

TOEP_C710616_38F_5_0.book 148 ページ 2013年12月4日 水曜日 午前9時56分