2 mechanical installation, Mechanical installation, 2mechanical installation – Yaskawa CIMR-LU Drives User Manual
Page 17: Installation environment
2 Mechanical Installation
YASKAWA ELECTRIC TOEP C710616 38F YASKAWA AC Drive L1000A Quick Start Guide
17
Mec
h
an
ic
al
In
st
al
lat
io
n
2
2
Mechanical Installation
◆ Mechanical Installation
This section outlines specifications, procedures, and the environment for proper mechanical installation of the drive.
CAUTION! Crush Hazard. Carrying the drive by the front cover may cause the main body of the drive to fall, resulting in minor or
moderate injury. Always hold the case when carrying the drive.
■
Installation Environment
Install the drive in an environment matching the specifications below to help prolong the optimum performance life of the
drive.
Table 2 Installation Environment
NOTICE: Avoid placing drive peripheral devices, transformers, or other electronics near the drive as the noise created can lead to
erroneous operation. If such devices must be used in close proximity to the drive, take proper steps to shield the drive from noise.
NOTICE: Prevent foreign matter such as metal shavings and wire clippings from falling into the drive during installation. Failure to
comply could result in damage to the drive. Place a temporary cover over the top of the drive during installation. Remove the temporary
cover before startup, as the cover will reduce ventilation and cause the drive to overheat.
Environment
Conditions
Installation Area
Indoors
Ambient Temperature
IP00 enclosure with top protective cover: -10 to +40
°C (14 to 104°F)
IP00 enclosure: -10 to +50
°C (14 to 122°F)
Drive reliability improves in environments without wide temperature fluctuations.
When using the drive in an enclosure panel, install a cooling fan or air conditioner in the area to ensure that the air
temperature inside the enclosure does not exceed the specified levels.
Do not allow ice to develop on the drive.
Humidity
95% RH or less and free of condensation
Storage Temperature
-20 to 60
°C (-4 to 140°F)
Surrounding Area
Install the drive in an area free from:
• oil mist and dust
• metal shavings, oil, water or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight
Altitude
1000 m or lower, up to 3000 m with derating 1000 m (3280 ft.) or lower, up to 3000 m (9842 ft.) with derating
(Refer to
)
Vibration
10 to 20 Hz at 9.8 m/s
2
20 to 55 Hz at 5.9 m/s
2
(CIMR-LU2A0008 to 2A0180, 4A0005 to 4A0150, and 5A0003 to 5A0077)
2.0 m/s
2
(CIMR-LU2A0215 to 2A0415, CIMR-LU4A0180 to 4A0605, and 5A0099 to 5A0200)
Orientation
Install the drive vertically to maintain maximum cooling effects.
TOEP_C710616_38F_5_0.book 17 ページ 2013年12月4日 水曜日 午前9時56分